UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

PET/CT Motion Correction Exploiting Motion Models Fit on Coarsely Gated Data Applied to Finely Gated Data

Whitehead, Alexander C; Su, Kuan-Hao; Wollenweber, Scott D; McClelland, Jamie R; Thielemans, Kris; (2024) PET/CT Motion Correction Exploiting Motion Models Fit on Coarsely Gated Data Applied to Finely Gated Data. In: 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). IEEE: Milan, Italy. Green open access

[thumbnail of mic_submission_2022_mm.pdf]
Preview
Text
mic_submission_2022_mm.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Motion correction is imperative to the reduction of blurring and artefacts inherent in PET; due to the relatively long acquisition time, and the temporal difference in the attenuation map acquisition. Registration literature contains many examples of spatial regularisers, however there are few temporal regularisers. Motion models can act as such a temporal regulariser, as well as allowing for the interpolation of unseen motion correction results. In our previous work, we applied a motion modelling approach to high TOF resolution non-attenuation corrected data; where the data was corrected to the space of the attenuation map. However, this approach was challenging, especially when low contrast lung tumours are present. This work seeks to extend previous work, by incorporating an approach suggested by Y. Lu et al. (JNM 2018), to perform an initial MLACF reconstruction for the motion estimation. In this work, we combine these two approaches, with several improvements, including; µ-map alignment, as well as, fitting the motion model on low noise low temporal/gate resolution data, and applying it to high noise high temporal/gate resolution data. To test this, XCAT volumes are constructed, and TOF data simulated. Evaluation compares the results of the proposed method against, where the motion model was fit on data gated more finely, where the motion model was fit on noiseless data, and finally non-motion corrected examples. Results indicate that the incorporation of MLACF, and fitting of the motion model on low noise low temporal/gate resolution data, improves contrast and quantification, while allowing for a relatively fast execution time.

Type: Proceedings paper
Title: PET/CT Motion Correction Exploiting Motion Models Fit on Coarsely Gated Data Applied to Finely Gated Data
Event: 2022 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference
Dates: 5 Nov 2022 - 12 Nov 2022
ISBN-13: 978-1-6654-8873-0
Open access status: An open access version is available from UCL Discovery
DOI: 10.1109/NSS/MIC44845.2022.10399154
Publisher version: http://dx.doi.org/10.1109/nss/mic44845.2022.103991...
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Motion estimation; Fitting; Logic gates; Attenuation; Data models; Spatial resolution; Tumors
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Chemical Engineering
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
URI: https://discovery.ucl.ac.uk/id/eprint/10188981
Downloads since deposit
6Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item