UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Central composite rotatable design for optimization of trihalomethane extraction and detection through gas chromatography: a case study

Rasheed, S; Hashmi, I; Zhou, Q; Kim, JK; Campos, LC; (2022) Central composite rotatable design for optimization of trihalomethane extraction and detection through gas chromatography: a case study. International Journal of Environmental Science and Technology 10.1007/s13762-022-04070-6. (In press). Green open access

[thumbnail of Campos_Central composite rotatable design for optimization of trihalomethane extraction and detection through gas chromatography_AOP.pdf]
Preview
Text
Campos_Central composite rotatable design for optimization of trihalomethane extraction and detection through gas chromatography_AOP.pdf

Download (3MB) | Preview

Abstract

Central composite rotatable design (CCRD) was employed to optimize initial temperature (ºC), ramp function (ºC/min) and salt addition for trihalomethane extraction/quantification from the drinking water distribution network in Ratta Amral, Rawalpindi., Pakistan. Drinking water samples were collected from the treatment plant, overhead reservoir and consumer’s taps. The USEPA method for trihalomethane detection 551.1 via gas chromatography was applied using liquid–liquid extraction. The experiments with input variables for sample preparation and operational conditions were performed in a randomized order as per design of experiment by central composite rotatable design and responses were evaluated for model development. A significant (p = 0.005) two-factor interaction model was optimized. Initial temperature was observed to be insignificant (p = 0.64), while ramp function (p = 0.0043) and salt addition (p = 0.04) were significant. Product of salt addition and ramp was significant (p = 0.004), while product of initial temperature and salt addition was insignificant (p = 0.008). With a desirability function of 0.97, an initial temperature of 50 ºC, 6 ºC rise/min to 180 ºC and 0.5 g salt were optimized. It was found that development and optimization of the analytical methods for rapid trihalomethane detection would improve optimization of the current treatment practices in the country.

Type: Article
Title: Central composite rotatable design for optimization of trihalomethane extraction and detection through gas chromatography: a case study
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s13762-022-04070-6
Publisher version: https://doi.org/10.1007/s13762-022-04070-6
Language: English
Additional information: © 2022 Springer Nature Switzerland AG. Part of Springer Nature. This article is licensed under a Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).
Keywords: Drinking water, Central composite rotatable design (CCRD), Pakistan, Trihalomethanes, Treatment plant, Gas chromatography
UCL classification: UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL
URI: https://discovery.ucl.ac.uk/id/eprint/10146835
Downloads since deposit
Loading...
39Downloads
Download activity - last month
Loading...
Download activity - last 12 months
Loading...
Downloads by country - last 12 months
Loading...

Archive Staff Only

View Item View Item