UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

PET/CT imaging of 3D printed devices in the gastrointestinal tract of rodents

Goyanes, A; Fernández-Ferreiro, A; Majeed, A; Gomez-Lado, N; Awad, A; Luaces-Rodríguez, A; Gaisford, S; ... Basit, AW; + view all (2017) PET/CT imaging of 3D printed devices in the gastrointestinal tract of rodents. International Journal of Pharmaceutics , 536 (1) pp. 158-164. 10.1016/j.ijpharm.2017.11.055. Green open access

[thumbnail of Basit Manuscript vf..pdf]
Preview
Text
Basit Manuscript vf..pdf - Accepted Version

Download (827kB) | Preview

Abstract

Fused deposition modelling (FDM) 3D printing (3DP) is a revolutionary technology with the potential to transform drug product design in both the pre-clinical and clinical arena. The objective of this pilot study was to explore the intestinal behaviour of four different polymer-based devices fabricated using FDM 3DP technology in rats. Small capsular devices of 8.6 mm in length and 2.65 mm in diameter were printed from polyvinyl alcohol-polyethylene glycol graft-copolymer (PVA-PEG copolymer, Kollicoat IR), hydroxypropylcellulose (HPC, Klucel), ethylcellulose (EC, Aqualon N7) and hypromellose acetate succinate (HPMCAS, Aquasolve-LG). A smaller sized device, 3.2 mm in length and 2.65 mm in diameter, was also prepared with HPMCAS to evaluate the cut off size of gastric emptying of solid formulations in rats. The devices were radiolabelled with Fluorodeoxyglucose (18F-FDG) and small animal positron emission tomography/computed tomography (microPET/CT) was used to track the movement and disintegration of the fabricated devices in the rats. The PVA-PEG copolymer and HPC devices disintegrated after 60min following oral administration. The EC structures did not disintegrate in the gastrointestinal tracts of the rats, whereas the HPMCAS-based systems disintegrated after 420 min. Interestingly, it was noted that the devices which remained intact over the course of the study had not emptied from the stomach of the rats. This was also the case with the smaller sized device. In summary, we report for the first time, the use of a microPET/CT imaging technique to evaluate the in vivo behaviour of 3D printed formulations. The manipulation of the 3D printed device design could be used to fabricate dosage forms of varying sizes and geometries with better gastric emptying characteristics suitable for rodent administration. The increased understanding of the capabilities of 3DP in dosage form design could, henceforth, accelerate pre-clinical testing of new drug candidates in animal models.

Type: Article
Title: PET/CT imaging of 3D printed devices in the gastrointestinal tract of rodents
Location: Netherlands
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.ijpharm.2017.11.055
Publisher version: https://doi.org/10.1016/j.ijpharm.2017.11.055
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Additive manufacturing, Computed tomography, Fused deposition modeling, Positron emission tomography, Printlets(TM), Three dimensional printing
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > UCL School of Pharmacy
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > UCL School of Pharmacy > Pharmaceutics
URI: https://discovery.ucl.ac.uk/id/eprint/10041542
Downloads since deposit
538Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item