UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Platelet activation and clotting cascade 3 activation by dialyzers designed for high AQ1 4 volume online hemodiafiltration

Tangvoraphonkchai, K; Riddell, A; Davenport, A; (2018) Platelet activation and clotting cascade 3 activation by dialyzers designed for high AQ1 4 volume online hemodiafiltration. Hemodialysis International , 22 (2) pp. 192-200. 10.1111/hdi.12586. Green open access

[thumbnail of Davenport-A_platelet activation_for high AQ1_4 volume online hem_.pdf]
Preview
Text
Davenport-A_platelet activation_for high AQ1_4 volume online hem_.pdf - Accepted Version

Download (221kB) | Preview

Abstract

INTRODUCTION: Hemodialysis patients are pro-thrombotic. Higher volume online postdilutional hemodiafiltration (OL-HDF), with increasing hematocrit increases the risk of clotting in the extracorporeal circuit (ECC). We wished to determine whether OL-HDF increased platelet activation and ECC clotting. METHODS: Coagulation parameters, platelet, white cell, and endothelial activation markers were measured at the start and end of dialysis sessions in 10 patients and also pre- and post-dialyzer after 15 minutes using two different dialyzers designed for high volume OL-HDF; cellulose triacetate (TAGP) and polysulphone (PS), and polyvinylpyrrolidone (PVP). Patients were anticoagulated with a heparin bolus. FINDINGS: At the start of OL-HDF, D dimers, thrombin antithrombin complexes (TATs), and soluble adhesions molecules (sICAM-1 and sVCAM-1) were increased. Post-treatment soluble P selectin (PS/PVP 26.7 ± 7.1 versus 36.6 ± 9.9; TAGP 28.7 ± 7.2 versus 43.5 ± 8.4 ng/ml, P < 0.001), and soluble CD40 ligand (PS/PVP 297 ± 228 versus 552 ± 272, TAGP 245 ± 187 versus 390 ± 205 ng/ml, P < 0.05) increased. Post-dialyzer concentrations increased versus pre-dialyzer for tissue factor (PS/PVP 117 ± 12 versus 136 ± 16, TAGP 100 ± 25 versus 128 ± 40 ng/ml, P < 0.05), factor VIIIc (PS/PVP 174 ± 54 versus 237 ± 83, TAGP 163 ± 60 versus 247 ± 102 IU/ml, P < 0.01), sVCAM-1 (PS/PVP 782 ± 64 versus 918 ± 140, TAGP 722 ± 121 versus 889 ± 168 ng/ml, P < 0.01), and D-dimers (PS/PVP 292 ± 132 versus 355 ± 167, TAGP 300 ± 129 versus 391 ± 171 ng/ml, P < 0.001). There was no macroscopic thrombus noted in the ECC, and no increase in microparticles, platelet factor-4, or TATs. DISCUSSION: Despite being pro-thrombotic, with activation of platelets, and lymphocytes during passage through ECC, no macroscopic clotting, or increased TATs were noted during OL-HDF, and no major differences between cellulosic and polysulphone dialyzers.

Type: Article
Title: Platelet activation and clotting cascade 3 activation by dialyzers designed for high AQ1 4 volume online hemodiafiltration
Open access status: An open access version is available from UCL Discovery
DOI: 10.1111/hdi.12586
Publisher version: http://dx.doi.org/10.1111/hdi.12586
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/1566750
Downloads since deposit
67Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item