UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Difference in hemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: Insights from a pre-clinical endothelial shear stress study

Tenekecioglu, E; Torii, R; Bourantas, C; Sotomi, Y; Cavalcante, R; Zeng, Y; Suwannasom, P; ... Serruys, P; + view all (2017) Difference in hemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: Insights from a pre-clinical endothelial shear stress study. EuroIntervention (In press).

[thumbnail of Torii_Tenekecioglu_et_al-Eurointervention-2017.pdf] Text
Torii_Tenekecioglu_et_al-Eurointervention-2017.pdf - Accepted Version
Access restricted to UCL open access staff

Download (1MB)

Abstract

BACKGROUND: In silico studies have provided robust evidence that stent design affects local hemodynamic forces, which appear as a major determinant of clinical outcomes following stent implantation. However, implications of different stent/scaffold configurations on local hemodynamic forces have not yet been investigated in vivo in a comparative fashion. METHOD AND RESULTS: Eight healthy mini pigs were implanted with six Absorb everolimus-eluting Bioresorbable Vascular Scaffolds (Absorb BVS) and five Mirage sirolimus-eluting Bioresorbable Microfiber Scaffolds (Mirage BRMS). Optical coherence tomography (OCT) was performed and strut protrusion was assessed post scaffold implantation. Following the reconstruction of coronary anatomy blood flow simulation was performed and endothelial shear stress (ESS) was estimated on top of the struts and at luminal surface between the struts in each scaffold. The thicker struts in Absorb (152±140µm) resulted in an increased protruded distance compared to Mirage (117±123 µm) (p=0.003). This had an effect in the local hemodynamic microenvironment. ESS at top-of-the struts were higher in Absorb (1.69±1.20 Pa) than in Mirage (1.53±0.91 Pa), (p<0.001) but lower at inter-strut zones (0.60±0.51Pa vs 0.63±0.50 Pa; p<0.01) compared to Mirage. Both scaffold types revealed comparable percentages of vessel luminal surface exposed to recirculation. CONCLUSION: Absorb demonstrated higher shear stress on top of the struts compared to Mirage. However, in the inter-struts zones shear stress was higher in Mirage than in Absorb. Further research is required to examine potential value of in vivo computational modeling in optimizing scaffold configuration and clinical outcomes.

Type: Article
Title: Difference in hemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: Insights from a pre-clinical endothelial shear stress study
Location: Washington, DC
Publisher version: https://www.pcronline.com/eurointervention/ahead-o...
Language: English
Keywords: Science & Technology, Life Sciences & Biomedicine, Cardiac & Cardiovascular Systems, Cardiovascular System & Cardiology; Bioresorbable scaffold; endothelial shear stress; scaffold design; strut geometry; hemodynamic microenvironment
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering
URI: https://discovery.ucl.ac.uk/id/eprint/1561762
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item