UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Assignment Of Opsonic Values To Pneumococcal Reference Serum 007SP For Use In Opsonophagocytic Assays For 13 Serotypes

Burton, RL; Antonello, J; Cooper, D; Goldblatt, D; Kim, KH; Plikaytis, BD; Roalfe, L; ... Akkoyunlu, M; + view all (2017) Assignment Of Opsonic Values To Pneumococcal Reference Serum 007SP For Use In Opsonophagocytic Assays For 13 Serotypes. Clinical and Vaccine Immunology , 24 (2) , Article e00457-16. 10.1128/CVI.00457-16. Green open access

[thumbnail of Burton_Assignment Of Opsonic Values To Pneumococcal Reference Serum 007SP For Use In Opsonophagocytic Assays For 13 Serotypes.pdf]
Preview
Text
Burton_Assignment Of Opsonic Values To Pneumococcal Reference Serum 007SP For Use In Opsonophagocytic Assays For 13 Serotypes.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Opsonophagocytic assays (OPAs) are routinely used for assessing the immunogenicity of pneumococcal vaccines, with OPA data often utilized for licensure of new vaccine formulations. However, no reference serum for pneumococcal OPAs is available, making evaluation of data among different laboratories difficult. This international collaboration was initiated to: 1) assign consensus opsonic indexes (OIs) to Pneumococcal Reference Serum Lot 007sp ("007sp") and a panel of calibration sera; and 2) determine if normalization with 007sp decreases the OPA variability among laboratories.To meet these goals, six participating laboratories tested a panel of sera in five runs for 13 serotypes. For each serum, consensus OIs were obtained using a mixed effects ANOVA model. For the calibration sera, normalized consensus values were also determined based on 007sp.For each serotype, the overall reduction in inter-laboratory variability was calculated by comparing the coefficients of variation of the unadjusted and the normalized values. Normalization of the results substantially reduced the inter-laboratory variability, ranging from a 15% reduction in variability for serotype 9V to 64% for serotype 7F. Normalization also increased the proportion of data within 2-fold of the consensus value from approximately 70% (average of all serotypes) to >90%.Based on the data obtained in this study, Pneumococcal Reference Standard Lot 007sp will likely be a useful reagent for normalizing pneumococcal OPA results from different laboratories. The data also support the use of the 16 FDA OPA calibration sera as part of the initial evaluation of new assays or periodic assessment of established assays.

Type: Article
Title: Assignment Of Opsonic Values To Pneumococcal Reference Serum 007SP For Use In Opsonophagocytic Assays For 13 Serotypes
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1128/CVI.00457-16
Publisher version: https://dx.doi.org/10.1128/CVI.00457-16
Language: English
Additional information: Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Keywords: 007sp, OPA, opsonic, pneumococcus, standardization
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health > Infection, Immunity and Inflammation Dept
URI: https://discovery.ucl.ac.uk/id/eprint/1534389
Downloads since deposit
184Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item