Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study

Zarifi, M; Guatelli, S; Bolst, D; Hutton, B; Rosenfeld, A; Qi, Y; (2017) Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study. Physica Medica , 33 pp. 197-206. 10.1016/j.ejmp.2016.12.011. Green open access

[thumbnail of Hutton_PaperGeant4_Manuscript_ Melek Zarifi-revision-sub.pdf]
Preview
Text
Hutton_PaperGeant4_Manuscript_ Melek Zarifi-revision-sub.pdf - Accepted Version

Download (1MB) | Preview

Abstract

In this paper we report a Geant4 simulation study to investigate the characteristic prompt gamma (PG) emission in a water phantom for real-time monitoring of the Bragg peak (BP) during proton beam irradiation. The PG production, emission spatial correlation with the BP, and position preference for detection with respect to the BP have been quantified in different PG energy windows as a function of proton pencil-beam energy from 100 to 200 MeV. The PG response to small BP shifts was evaluated using a 2 cm-thick slab with different human body materials embedded in a water phantom. Our results show that the prominent characteristic PG emissions of 4.44, 5.21 and 6.13 MeV exhibit distinctive correlation with the dose deposition curve. The accuracy in BP position identification using these characteristic PG rays is highly consistent as the beam energy increases from 100 to 200 MeV. There exists a position preference for PG detection with respect to the BP position, which has a strong dependence on the proton beam energy and PG energies. It was also observed that a submillimeter shift of the BP position can be realized by using PG signals. These results indicate that the characteristic PG signal is sensitive and reliable for BP tracking. Although the maximization of the PG measurement associated with the BP is difficult, it can be optimized with energy and detection position preferences.

Type: Article
Title: Characterization of prompt gamma-ray emission with respect to the Bragg peak for proton beam range verification: A Monte Carlo study
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.ejmp.2016.12.011
Publisher version: http://doi.org/10.1016/j.ejmp.2016.12.011
Language: English
Additional information: © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved. This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Science & Technology, Life Sciences & Biomedicine, Radiology, Nuclear Medicine & Medical Imaging, Prompt gamma, Bragg peak, Proton therapy, Geant4, COMPTON CAMERA, THERAPY, SIMULATION, PET, IRRADIATION, PATIENT, SLIT
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Department of Imaging
URI: https://discovery.ucl.ac.uk/id/eprint/1534323
Downloads since deposit
197Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item