UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Why Not to Use the Handgrip Test in the Assessment of Cardiovascular Autonomic Neuropathy Among Patients with Diabetes Mellitus?

Körei, AE; Kempler, M; Istenes, I; Vági, OE; Putz, Z; Horváth, VJ; Keresztes, K; ... Kempler, P; + view all (2017) Why Not to Use the Handgrip Test in the Assessment of Cardiovascular Autonomic Neuropathy Among Patients with Diabetes Mellitus? Curr Vasc Pharmacol , 15 (1) pp. 66-73. 10.2174/1570161114666160822154351. Green open access

[thumbnail of Tabak_K%C3%B6rei%20A%20handgrip%202016%20Curr%20Vasc%20Pharm%20final%20(3).pdf]
Preview
Text
Tabak_K%C3%B6rei%20A%20handgrip%202016%20Curr%20Vasc%20Pharm%20final%20(3).pdf - Accepted Version

Download (342kB) | Preview

Abstract

OBJECTIVE: Historically, a set of 5 Cardiovascular Autonomic Reflex Tests (CARTs) were considered to be the gold standard in the assessment of Cardiovascular Autonomic Neuropathy (CAN). However, measuring diastolic Blood Pressure (BP) response to sustained handgrip is omitted in recent guidelines. We aimed to assess the association between the handgrip and the other 4 tests as well as to identify determinants of the handgrip test results in diabetic patients. PATIENTS AND METHODS: 353 patients with diabetes (DM) were recruited (age: 60.2±7.4 years; female: 57.2%; BMI: 29.3±2.1 kg/m2; DM duration: 15.6±9.9 years; HbA1c: 7.8±1.4% (66 mmol/mol); with type 1 DM: 18.1%). CAN was assessed by 5 CARTs: the deep breathing test, Valsalva ratio, 30/15 ratio, handgrip and orthostatic hypotension test. RESULTS: Sensitivity and specificity of the handgrip test in the diagnosis of definite CAN were 24.6% (95%CI 17.7-33.1%) and 79.4% (95%CI 73.3-84.4%), respectively. Results of the handgrip test did not show any association with those of the deep-breathing test (y=0.004, p=0.563), 30/15 ratio (y=0.282, p=0.357), Valsalva ratio (y=-0.058, p=0.436) and orthostatic hypotension (y=-0.026, p=0.833). Handgrip test abnormality showed an independent association with higher initial diastolic BP (OR 1.05, p=0.0009) and an independent inverse association with the presence of hypertension (OR=0.42, p=0.006). CONCLUSION: Our data confirm that the handgrip test should no longer be part of the cardiovascular autonomic testing being highly dependent on hypertensive status and baseline diastolic BP. Exaggerated exercise pressor response is proposed as putative mechanism for the inverse association between abnormal results of the handgrip test and hypertension. Adequate CARTs are important to allow their use in clinical trials and for the prevention of DM-associated complications by initiating early treatment.

Type: Article
Title: Why Not to Use the Handgrip Test in the Assessment of Cardiovascular Autonomic Neuropathy Among Patients with Diabetes Mellitus?
Location: United Arab Emirates
Open access status: An open access version is available from UCL Discovery
DOI: 10.2174/1570161114666160822154351
Publisher version: http://dx.doi.org/10.2174/157016111466616082215435...
Language: English
Additional information: The published manuscript is available at EurekaSelect via http://www.eurekaselect.com/openurl/content.php?genre=article&doi=10.2174/1570161114666160822154351.
Keywords: Diabetes; cardiovascular autonomic neuropathy; handgrip test; hypertension
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health > Epidemiology and Public Health
URI: https://discovery.ucl.ac.uk/id/eprint/1508823
Downloads since deposit
310Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item