UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Towards higher sensitivity and stability of axon diameter estimation with diffusion-weighted MRI.

Sepehrband, F; Alexander, DC; Kurniawan, ND; Reutens, DC; Yang, Z; (2016) Towards higher sensitivity and stability of axon diameter estimation with diffusion-weighted MRI. NMR in Biomedicine , 29 (3) pp. 293-308. 10.1002/nbm.3462. Green open access

[thumbnail of Sepehrband_et_al-2016-NMR_in_Biomedicine.pdf]
Preview
Text
Sepehrband_et_al-2016-NMR_in_Biomedicine.pdf - Published Version

Download (4MB) | Preview

Abstract

Diffusion-weighted MRI is an important tool for in vivo and non-invasive axon morphometry. The ActiveAx technique utilises an optimised acquisition protocol to infer orientationally invariant indices of axon diameter and density by fitting a model of white matter to the acquired data. In this study, we investigated the factors that influence the sensitivity to small-diameter axons, namely the gradient strength of the acquisition protocol and the model fitting routine. Diffusion-weighted ex. vivo images of the mouse brain were acquired using 16.4-T MRI with high (Gmax of 300 mT/m) and ultra-high (Gmax of 1350 mT/m) gradient strength acquisitions. The estimated axon diameter indices of the mid-sagittal corpus callosum were validated using electron microscopy. In addition, a dictionary-based fitting routine was employed and evaluated. Axon diameter indices were closer to electron microscopy measures when higher gradient strengths were employed. Despite the improvement, estimated axon diameter indices (a lower bound of ~ 1.8 μm) remained higher than the measurements obtained using electron microscopy (~1.2 μm). We further observed that limitations of pulsed gradient spin echo (PGSE) acquisition sequences and axonal dispersion could also influence the sensitivity with which axon diameter indices could be estimated. Our results highlight the influence of acquisition protocol, tissue model and model fitting, in addition to gradient strength, on advanced microstructural diffusion-weighted imaging techniques. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

Type: Article
Title: Towards higher sensitivity and stability of axon diameter estimation with diffusion-weighted MRI.
Open access status: An open access version is available from UCL Discovery
DOI: 10.1002/nbm.3462
Publisher version: http://dx.doi.org/10.1002/nbm.3462
Language: English
Additional information: © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: ActiveAx, axon diameter index, diffusion-weighted MRI, electron microscopy, histological validation, mouse corpus callosum, ultra-high gradient strength
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/1475049
Downloads since deposit
107Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item