UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

An optimized ultrasound detector for photoacoustic breast tomography

Xia, W; Piras, D; van Hespen, JCG; van Veldhoven, S; Prins, C; van Leeuwen, TG; Steenbergen, W; (2013) An optimized ultrasound detector for photoacoustic breast tomography. Medical Physics , 40 (3) , Article 032901. 10.1118/1.4792462. Green open access

[thumbnail of Xia_photoacoustic breast tomography_revised.pdf]
Preview
Text
Xia_photoacoustic breast tomography_revised.pdf

Download (3MB) | Preview

Abstract

Purpose: Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the expected photoacoustic frequency bandwidth (a few MHz to tens of kHz) is inversely proportional to the dimensions of light absorbing structures (0.5–10+ mm), proper choices of materials and their geometries and proper considerations in design have to be made to implement optimal photoacoustic detectors. In this study, we design and evaluate a specialized ultrasound detector for photoacoustic mammography. Methods: Based on the required detector sensitivity and its frequency response, a selection of active material and matching layers and their geometries is made leading to functional detector models. By iteration between simulation of detector performances, fabrication and experimental characterization of functional models an optimized implementation is made and evaluated. For computer simulation, we use 1D Krimholtz–Leedom–Matthaei and 3D finite-element based models. Results: The experimental results of the designed first and second functional detectors matched with the simulations. In subsequent bare piezoelectric samples the effect of lateral resonances was addressed and their influence minimized by subdicing the samples. Consequently, using simulations, a final optimized detector was designed, with a center frequency of 1 MHz and a −6 dB bandwidth of 0.4–1.25 MHz (fractional bandwidth of ∼80%). The minimum detectable pressure was measured to be 0.5 Pa. Conclusions: A single-element, large-aperture, sensitive, and broadband detector is designed and developed for photoacoustic tomography of the breast. The detector should be capable of detecting vascularized tumors with 1–2 mm resolution. The minimum detectable pressure is 0.5 Pa, which will facilitate deeper imaging compared to the current systems. Further improvements by proper electrical grounding and shielding and implementation of this design into an arrayed detector will pave the way for clinical applications of photoacoustic mammography.

Type: Article
Title: An optimized ultrasound detector for photoacoustic breast tomography
Open access status: An open access version is available from UCL Discovery
DOI: 10.1118/1.4792462
Publisher version: http://dx.doi.org/10.1118/1.4792462
Language: English
Additional information: Copyright 2013 AIP Publishing. This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. The following article appeared in Xia, W; Piras, D; van Hespen, JCG; van Veldhoven, S; Prins, C; van Leeuwen, TG; Steenbergen, W; (2013) An optimized ultrasound detector for photoacoustic breast tomography. Medical Physics, 40 (3), Article 032901. 10.1118/1.4792462, and may be found at http://dx.doi.org/10.1118/1.4792462.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/1450827
Downloads since deposit
206Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only