UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Evaluation of air-displacement plethysmography in children aged 5-7 years using a three-component model of body composition

Wells, JCK; Fuller, NJ; Wright, A; Fewtrell, MS; Cole, TJ; (2003) Evaluation of air-displacement plethysmography in children aged 5-7 years using a three-component model of body composition. BRIT J NUTR , 90 (3) 699 - 707. 10.1079/BJN2003930. Green open access

[thumbnail of 14493.pdf]
Preview
PDF
14493.pdf

Download (152kB)

Abstract

The aim of the present study was to evaluate air-displacement plethysmography (ADP) in children aged 5-7 years. Body-composition measurements were obtained by ADP, H-2 dilution and anthropometry in twenty-eight children. Calculation of body volume by ADP was undertaken using adult and children's equations for predicting lung volume and surface area. Fat-free mass (FFM) was calculated using a three-component model. Measured FFM hydration was then compared with values from the reference child. Differences between measured and reference hydration were back-extrapolated, to calculate the error in ADP that would account for any disagreement. Propagation of error was used to distinguish the contributions of methodological precision and biological variability to total hydration variability. The use of children's equations influenced the results for lung volume but not surface area. The mean difference between measured and reference hydration was 0.6 (SD 1.7) % (P<0.10), equivalent to an error in body volume of 0.04 (So 0.20) litres (P<0.30), and in percentage fat of 0.4 (SD 1.9) (P<0.28). The limits of agreement in individuals could be attributed to methodological precision and biological variability in hydration. It is concluded that accuracy of ADP was high for the whole group, with a mean bias of <0.5% fat using the three-component model, and after taking into account biological variability in hydration, the limits of agreement were around 2 % fat in individuals. Paediatric rather than adult equations for lung volume estimation should be used.

Type: Article
Title: Evaluation of air-displacement plethysmography in children aged 5-7 years using a three-component model of body composition
Open access status: An open access version is available from UCL Discovery
DOI: 10.1079/BJN2003930
Publisher version: http://dx.doi.org/10.1079/BJN2003930
Language: English
Keywords: fat mass, fat-free mass, bodpod, body composition, children, FAT-FREE MASS, 4-COMPONENT MODEL, REFERENCE CURVES, WHITE-CHILDREN, X-RAY, ADULTS, HYDRATION, HYDRODENSITOMETRY, DENSITY, VALIDATION
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > UCL GOS Institute of Child Health > Population, Policy and Practice Dept
URI: https://discovery.ucl.ac.uk/id/eprint/14493
Downloads since deposit
413Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item