UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Modelling temporal stability of EPI time series using magnitude images acquired with multi-channel receiver coils.

Hutton, C; Balteau, E; Lutti, A; Josephs, O; Weiskopf, N; (2012) Modelling temporal stability of EPI time series using magnitude images acquired with multi-channel receiver coils. PLoS One , 7 (12) , Article e52075. 10.1371/journal.pone.0052075. Green open access

[thumbnail of 1381488.pdf]
Preview
PDF
1381488.pdf

Download (879kB)

Abstract

In 2001, Krueger and Glover introduced a model describing the temporal SNR (tSNR) of an EPI time series as a function of image SNR (SNR(0)). This model has been used to study physiological noise in fMRI, to optimize fMRI acquisition parameters, and to estimate maximum attainable tSNR for a given set of MR image acquisition and processing parameters. In its current form, this noise model requires the accurate estimation of image SNR. For multi-channel receiver coils, this is not straightforward because it requires export and reconstruction of large amounts of k-space raw data and detailed, custom-made image reconstruction methods. Here we present a simple extension to the model that allows characterization of the temporal noise properties of EPI time series acquired with multi-channel receiver coils, and reconstructed with standard root-sum-of-squares combination, without the need for raw data or custom-made image reconstruction. The proposed extended model includes an additional parameter κ which reflects the impact of noise correlations between receiver channels on the data and scales an apparent image SNR (SNR'(0)) measured directly from root-sum-of-squares reconstructed magnitude images so that κ = SNR'(0)/SNR(0) (under the condition of SNR(0)>50 and number of channels ≤32). Using Monte Carlo simulations we show that the extended model parameters can be estimated with high accuracy. The estimation of the parameter κ was validated using an independent measure of the actual SNR(0) for non-accelerated phantom data acquired at 3T with a 32-channel receiver coil. We also demonstrate that compared to the original model the extended model results in an improved fit to human task-free non-accelerated fMRI data acquired at 7T with a 24-channel receiver coil. In particular, the extended model improves the prediction of low to medium tSNR values and so can play an important role in the optimization of high-resolution fMRI experiments at lower SNR levels.

Type: Article
Title: Modelling temporal stability of EPI time series using magnitude images acquired with multi-channel receiver coils.
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1371/journal.pone.0052075
Publisher version: http://dx.doi.org/10.1371/journal.pone.0052075
Language: English
Additional information: © 2012 Hutton et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. This research and open access to the publication were funded by the Wellcome Trust (091593/Z/10/Z). Data were acquired at the 7T MRI system at the Otto-von-Guericke University of Magdeburg, Germany which is supported by the Transregional Collaborative Research Centre SFB/TRR 62 “Companion-Technology for Cognitive Technical Systems” funded by the German Research Foundation (DFG). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Imaging Neuroscience
URI: https://discovery.ucl.ac.uk/id/eprint/1381488
Downloads since deposit
154Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item