UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Establishing a major cause of discrepancy in the calibration of Affymetrix GeneChips

Harrison, AP; Johnston, CE; Orengo, CA; (2007) Establishing a major cause of discrepancy in the calibration of Affymetrix GeneChips. BMC BIOINFORMATICS , 8 , Article 195. 10.1186/1471-2105-8-195. Green open access

[thumbnail of 1471-2105-8-195.pdf]
Preview
PDF
1471-2105-8-195.pdf

Download (868kB)

Abstract

Background: Affymetrix GeneChips are a popular platform for performing whole-genome experiments on the transcriptome. There are a range of different calibration steps, and users are presented with choices of different background subtractions, normalisations and expression measures. We wished to establish which of the calibration steps resulted in the biggest uncertainty in the sets of genes reported to be differentially expressed.Results: Our results indicate that the sets of genes identified as being most significantly differentially expressed, as estimated by the z-score of fold change, is relatively insensitive to the choice of background subtraction and normalisation. However, the contents of the gene list are most sensitive to the choice of expression measure. This is irrespective of whether the experiment uses a rat, mouse or human chip and whether the chip definition is made using probe mappings from Unigene, RefSeq, Entrez Gene or the original Affymetrix definitions. It is also irrespective of whether both Present and Absent, or just Present, Calls from the MAS5 algorithm are used to filter genelists, and this conclusion holds for genes of differing intensities. We also reach the same conclusion after assigning genes to be differentially expressed using t-statistics, although this approach results in a large amount of false positives in the sets of genes identified due to the small numbers of replicates typically used in microarray experiments.Conclusion: The major calibration uncertainty that biologists need to consider when analysing Affymetrix data is how their multiple probe values are condensed into one expression measure.

Type: Article
Title: Establishing a major cause of discrepancy in the calibration of Affymetrix GeneChips
Open access status: An open access version is available from UCL Discovery
DOI: 10.1186/1471-2105-8-195
Publisher version: http://dx.doi.org/10.1186/1471-2105-8-195
Language: English
Additional information: © 2007 Harrison et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Keywords: OLIGONUCLEOTIDE ARRAYS, MICROARRAY DATA, EXPRESSION, NORMALIZATION, GENE, MODEL
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > Div of Biosciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Life Sciences > Div of Biosciences > Structural and Molecular Biology
URI: https://discovery.ucl.ac.uk/id/eprint/1298884
Downloads since deposit
112Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item