UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Comparison Between a Medical-Grade Device and a Cuffless Consumer-Grade Device for Day and Night Blood Pressure Monitoring

Bhatt, B; Amir, H; Jones, S; Hughes, A; Orini, M; (2024) Comparison Between a Medical-Grade Device and a Cuffless Consumer-Grade Device for Day and Night Blood Pressure Monitoring. In: Computing in Cardiology. CinC (Computing in Cardiology) Green open access

[thumbnail of CinC2024-432.pdf]
Preview
PDF
CinC2024-432.pdf - Accepted Version

Download (1MB) | Preview

Abstract

Hypertension affects 1 in 3 adults worldwide and is the leading global cause of death. Most hypertension cases remain undiagnosed, which poses a serious threat to global health. To address this, wearable cuffless devices aim to unobtrusively monitor blood pressure (BP). Our aim was to validate a consumer-grade cuffless wearable blood pressure monitor (WBPM) using a medical-grade ambulatory device (ABPM), for reference. 29 participants (range 20-62 years old, 16 females) simultaneously wore the WBPM and ABPM for 24 hours. The ABPM measured at set intervals of 30 or 60 minutes, during day and nighttime respectively. Readings from the WBPM were automatically taken at rest only. Mean and standard deviation of systolic and diastolic BP readings were measured during 24-hours, during day (06:00-22:00) and night (20:00-06:00). Readings were paired if they were taken ≤10 minutes apart, and if heart rate was within ±10bpm. For all intervals, mean systolic and diastolic BP showed a low to moderate correlation (0.27 - 0.41), small biases (~ ±5 mmHg), large limits of agreement (~ ±30 mmHg for systolic and ±20 mmHg for diastolic) and median percentage absolute error ~10%. Agreement for standard deviation of BP was poor. This data can help to inform future research into the potential utility of WBPM in hypertension and cardiovascular disease prevention.

Type: Proceedings paper
Title: Comparison Between a Medical-Grade Device and a Cuffless Consumer-Grade Device for Day and Night Blood Pressure Monitoring
Event: 2024 Computing in Cardiology Conference
Open access status: An open access version is available from UCL Discovery
DOI: 10.22489/CinC.2024.432
Publisher version: https://cinc.org/final_program_papers_2024/
Language: English
Additional information: This work is licensed under a Creative Commons License. The images or other third-party material in this article are included in the Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10220913