Vanstrum, Erik B;
Ma, Runzhuo;
Maya-Silva, Jacqueline;
Sanford, Daniel;
Nguyen, Jessica H;
Lei, Xiaomeng;
Chevinksy, Michael;
... Hung, Andrew J; + view all
(2021)
Development and Validation of an Objective Scoring Tool to Evaluate Surgical Dissection: Dissection Assessment for Robotic Technique (DART).
Urology Practice
, 8
(5)
pp. 596-604.
10.1097/UPJ.0000000000000246.
|
Text
Development and validation of an objective scoring tool to evaluate surgical dissection Dissection Assessment for Robotic Te.pdf - Published Version Access restricted to UCL open access staff until 4 February 2026. Download (379kB) |
Abstract
Introduction:Evaluation of surgical competency has important implications for training new surgeons, accreditation, and improving patient outcomes. A method to specifically evaluate dissection performance does not yet exist. This project aimed to design a tool to assess surgical dissection quality.Methods:Delphi method was used to validate structure and content of the dissection evaluation. A multi-institutional and multi-disciplinary panel of 14 expert surgeons systematically evaluated each element of the dissection tool. Ten blinded reviewers evaluated 46 de-identified videos of pelvic lymph node and seminal vesicle dissections during the robot-assisted radical prostatectomy. Inter-rater variability was calculated using prevalence-adjusted and bias-adjusted kappa. The area under the curve from receiver operating characteristic curve was used to assess discrimination power for overall Dissection Assessment for Robotic Technique (DART) scores as well as domains in discriminating trainees (≤100 robotic cases) from experts (>100).Results:Four rounds of Delphi method achieved language and content validity in 27/28 elements. Use of 3 or 5-point scale remained contested; thus, both scales were evaluated during validation. The 3-point scale showed improved kappa for each domain. Experts demonstrated significantly greater total scores on both scales (3-point, p <0.001; 5-point, p <0.001). The ability to distinguish experience was equivalent for total score on both scales (3-point AUC=0.92, CI 0.82-1.00; 5-point AUC=0.92, CI 0.83-1.00).Conclusions:We present the development and validation of DART, an objective and reproducible 3-point surgical assessment to evaluate tissue dissection. DART can effectively differentiate levels of surgeon experience and can be used in multiple surgical steps.
| Type: | Article |
|---|---|
| Title: | Development and Validation of an Objective Scoring Tool to Evaluate Surgical Dissection: Dissection Assessment for Robotic Technique (DART) |
| Location: | United States |
| DOI: | 10.1097/UPJ.0000000000000246 |
| Publisher version: | https://doi.org/10.1097/upj.0000000000000246 |
| Language: | English |
| Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
| Keywords: | Science & Technology, Life Sciences & Biomedicine, Urology & Nephrology, robotic surgical procedures, education, interdisciplinary research, CROWD-SOURCED ASSESSMENT, SKILLS, COMPETENCE |
| UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention |
| URI: | https://discovery.ucl.ac.uk/id/eprint/10218357 |
Archive Staff Only
![]() |
View Item |