UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

[99mTc]Tc-sestamibi SPECT/CT for the diagnosis of kidney tumours: a multi-centre feasibility study (MULTI-MIBI Study)

Warren, Hannah; Wagner, Thomas; El-Sheikh, Soha; Campain, Nick; Wah, Tze M; O'Brien, Tim S; Mendichovszky, Iosif A; ... Tran, Maxine GB; + view all (2025) [99mTc]Tc-sestamibi SPECT/CT for the diagnosis of kidney tumours: a multi-centre feasibility study (MULTI-MIBI Study). European Journal of Nuclear Medicine and Molecular Imaging 10.1007/s00259-025-07525-3. (In press). Green open access

[thumbnail of Multi-mibi.pdf]
Preview
Text
Multi-mibi.pdf - Published Version

Download (1MB) | Preview

Abstract

Purpose: [99mTc]Tc-sestamibi SPECT/CT (MIBI SPECT/CT) is a promising tool to differentiate benign and malignant renal tumours. We tested feasibility of recruitment to a prospective, multi-centre diagnostic test evaluation study of MIBI SPECT/CT for T1 renal tumours. // Methods: Consecutive adult patients with a newly-diagnosed clinical T1 (cT1) renal mass (2–7 cm) presenting to participating sites December 2022 - February 2024 were recruited and underwent MIBI SPECT/CT prior to histopathological diagnosis. Patients who accepted and declined participation and clinicians involved in study activities were invited to a semi-structured interview. The primary endpoint was feasibility of multi-centre recruitment. Secondary endpoints included qualitative assessment of barriers and facilitators to participation, estimates of MIBI SPECT/CT accuracy to detect cancer in order to power a definitive study, inter-rater agreement and identifying training needs for scan acquisition and interpretation. // Results: Of 109 approached patients, 50 enrolled and underwent the study scan (45.8%, 95% CI 36.2–55.7%) across 6 sites. MIBI SPECT/CT scans were acquired and reported without the need for significant additional training. All scans were of adequate quality for interpretation. Sensitivity and specificity of MIBI SPECT/CT to detect cancer were 97.0% (95% CI 84.2–99.9%) and 53.8% (25.1–80.8%), respectively. // Conclusion: MULTI-MIBI has demonstrated feasibility of recruitment to a diagnostic evaluation study for T1 renal masses. Preliminary estimates of diagnostic accuracy suggest that MIBI SPECT/CT could reduce the number of patients with benign tumours undergoing surgery without missing a significant number of patients with malignant disease, however these results are limited by the small sample size in this feasibility study and a larger definitive study is needed prior to adoption in practice.

Type: Article
Title: [99mTc]Tc-sestamibi SPECT/CT for the diagnosis of kidney tumours: a multi-centre feasibility study (MULTI-MIBI Study)
Location: Germany
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s00259-025-07525-3
Publisher version: https://doi.org/10.1007/s00259-025-07525-3
Language: English
Additional information: This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Keywords: Renal cancer; Oncocytoma; Diagnostic accuracy; SPECT/CT; Sestamibi
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Surgical Biotechnology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention
URI: https://discovery.ucl.ac.uk/id/eprint/10214959
Downloads since deposit
1Download
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item