A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation

Liu, Y; Wang, L; Zhang, J; Liu, S; Zheng, J; Kang, J; Dong, E; ... Li, D; + view all (2025) A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation. Bio-Design and Manufacturing , 8 (2) pp. 275-287. 10.1631/bdm.2400259.

[thumbnail of Liu_A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation_AAM.pdf] Text
Liu_A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation_AAM.pdf
Access restricted to UCL open access staff until 2 March 2026.

Download (3MB)

Abstract

The bioinert nature of polyether ether ketone (PEEK) material limits the widespread clinical application of PEEK implants. Although the porous structure is considered to improve osseointegration of PEEK implants, it is hardly used due to its mechanical properties. This study investigated the combined influence of the porous structure and in vivo mechanical stimulation on implantation safety and bone growth based on finite element analysis of the biomechanical behavior of the implantation system. The combined control of pore size and screw preloads allows the porous PEEK implant to achieve good osseointegration while maintaining a relatively high safety level. A pore size of 600 µm and a preload of 0.05 N·m are the optimal combination for the long-term stability of the implant, with which the safety factor of the implant is >2, and the predicted percentage of effective bone growth area of the bone-implant interface reaches 97%. For further clinical application, PEEK implants were fabricated with fused filament fabrication (FFF) three-dimensional (3D) printing, and clinical outcomes demonstrated better bone repair efficacy and long-term stability of porous PEEK implants compared to solid PEEK implants. Moreover, good osteointegration performance of 3D-printed porous PEEK implants was observed, with an average bone volume fraction >40% three months after implantation. In conclusion, 3D-printed porous PEEK implants have great potential for clinical application, with validated implantation safety and good osseointegration.

Type: Article
Title: A design strategy for long-term stability of porous PEEK implants by regulation of porous structure and in vivo mechanical stimulation
DOI: 10.1631/bdm.2400259
Publisher version: https://doi.org/10.1631/bdm.2400259
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions.
Keywords: Porous polyether ether ketone (PEEK) implant, Osteointegration, Interface biomechanics, Maxillofacial implants, Finite element analyses, Fused filament fabrication (FFF) 3D printing
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Ortho and MSK Science
URI: https://discovery.ucl.ac.uk/id/eprint/10208266
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item