Lyu, Junpeng;
Pitt, Michael;
Broyd, Tim;
(2024)
The impact of IEQ in the university lecture theatres on students’ concentration levels in London.
Facilities
, 42
(9-10)
10.1108/F-04-2023-0036.
Preview |
Text
Pitt_lyu-pitt_The impact of IEQ.pdf Download (1MB) | Preview |
Abstract
Purpose: University students’ lecture theatre concentration levels are significantly related to indoor environmental quality (IEQ). The purpose of this study is to investigate the relationship between indoor environmental quality (IEQ) and the self-reported concentration levels of university students during the winter at University College London (UCL), UK.// Design/methodology/approach: A questionnaire survey and physical measurements were used to assess the IEQ factors affecting students’ concentration levels.// Findings: The lecture theatre design factor was the most significant factor influencing students’ concentration levels, and the facility environment was more important than the thermal environment, indoor air quality, and acoustic environment in influencing students’ concentration levels in this winter investigation at UCL, UK. Additionally, students prefer a colder thermal environment. The concentration level of students was positively correlated with the indoor air quality and negatively correlated with the acoustic environment.// Practical implications: Based on model application, this research could provide lecture theatre IEQ design. This research additionally provides an acceptable indoor thermal environment temperature range based on a large sample, which can be used to calibrate a student performance benchmark.// Originality/value: As this study evaluates the IEQ factors that influence the concentration levels of university students, interior designers and engineers should consider the rational layout of these factors. Therefore, this study may provide a reference for the interior environmental design of lecture theatres in educational buildings.
Type: | Article |
---|---|
Title: | The impact of IEQ in the university lecture theatres on students’ concentration levels in London |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1108/F-04-2023-0036 |
Publisher version: | https://doi.org/10.1108/F-04-2023-0036 |
Language: | English |
Additional information: | This version is the author-accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Facility environment, University student, Concentration level, Indoor environmental quality |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment |