Repeat it without me: Crowdsourcing the T1 mapping common ground via the ISMRM reproducibility challenge

Boudreau, Mathieu; Karakuzu, Agah; Cohen-Adad, Julien; Bozkurt, Ecem; Carr, Madeline; Castellaro, Marco; Concha, Luis; ... ISMRM Reproducible Research Study Group and the ISMRM Quantitati; + view all (2024) Repeat it without me: Crowdsourcing the T1 mapping common ground via the ISMRM reproducibility challenge. Magnetic Resonance in Medicine 10.1002/mrm.30111. (In press). Green open access

[thumbnail of Repeat it without me Crowdsourcing the T1 mapping common ground.pdf]
Preview
Text
Repeat it without me Crowdsourcing the T1 mapping common ground.pdf - Published Version

Download (3MB) | Preview

Abstract

PURPOSE: T1 mapping is a widely used quantitative MRI technique, but its tissue-specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well-established inversion-recovery T1 mapping technique, using acquisition details from a seminal T1 mapping paper on a standardized phantom and in human brains. METHODS: The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open-source platforms. Intersubmission and intrasubmission comparisons were performed. RESULTS: Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also developed: https://rrsg2020.dashboards.neurolibre.org. CONCLUSION: The T1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T1 variations in vivo.

Type: Article
Title: Repeat it without me: Crowdsourcing the T1 mapping common ground via the ISMRM reproducibility challenge
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1002/mrm.30111
Publisher version: http://dx.doi.org/10.1002/mrm.30111
Language: English
Additional information: © 2024 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: T1 mapping, inversion recovery, open data, quantitative MRI, reproducibility
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/10192414
Downloads since deposit
30Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item