UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Integrated-mode proton radiography with 2D lateral projections

Simard, Mikaël; Robertson, Daniel G; Fullarton, Ryan; Royle, Gary J; Beddar, Sam; Collins-Fekete, Charles-Antoine; (2024) Integrated-mode proton radiography with 2D lateral projections. Physics in Medicine & Biology , 69 (5) , Article 054001. 10.1088/1361-6560/ad209d. Green open access

[thumbnail of Simard_2024_Phys._Med._Biol._69_054001.pdf]
Preview
Text
Simard_2024_Phys._Med._Biol._69_054001.pdf

Download (3MB) | Preview

Abstract

Integrated-mode proton radiography leading to water equivalent thickness (WET) maps is an avenue of interest for motion management, patient positioning, and in vivo range verification. Radiographs can be obtained using a pencil beam scanning setup with a large 3D monolithic scintillator coupled with optical cameras. Established reconstruction methods either (1) involve a camera at the distal end of the scintillator, or (2) use a lateral view camera as a range telescope. Both approaches lead to limited image quality. The purpose of this work is to propose a third, novel reconstruction framework that exploits the 2D information provided by two lateral view cameras, to improve image quality achievable using lateral views. The three methods are first compared in a simulated Geant4 Monte Carlo framework using an extended cardiac torso (XCAT) phantom and a slanted edge. The proposed method with 2D lateral views is also compared with the range telescope approach using experimental data acquired with a plastic volumetric scintillator. Scanned phantoms include a Las Vegas (contrast), 9 tissue-substitute inserts (WET accuracy), and a paediatric head phantom. Resolution increases from 0.24 lp/mm (distal) to 0.33 lp/mm (proposed method) on the simulated slanted edge phantom, and the mean absolute error on WET maps of the XCAT phantom is reduced from 3.4 to 2.7 mm with the same methods. Experimental data from the proposed 2D lateral views indicate a 36\% increase in contrast relative to the range telescope method. High WET accuracy is obtained, with a mean absolute error of 0.4 mm over 9 inserts. Results are presented for various pencil beam spacing ranging from 2 to 6 mm. This work illustrates that high quality proton radiographs can be obtained with clinical beam settings and the proposed reconstruction framework with 2D lateral views, with potential applications in adaptive proton therapy.

Type: Article
Title: Integrated-mode proton radiography with 2D lateral projections
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6560/ad209d
Publisher version: http://dx.doi.org/10.1088/1361-6560/ad209d
Language: English
Additional information: Copyright © 2024 The Author(s). Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
Keywords: image-guided radiotherapy, integrated mode, proton imaging, proton radiography, proton therapy
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10186539
Downloads since deposit
11Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item