UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Using pulse oximeters in care homes for residents with COVID-19 and other conditions: a rapid mixed-methods evaluation

Sidhu, Manbinder; Litchfield, Ian; Miller, Robin; Fulop, Naomi J; Janta, Barbara; Tanner, Jamie-Rae; Maistrello, Giulia; ... Sussex, Jon; + view all (2022) Using pulse oximeters in care homes for residents with COVID-19 and other conditions: a rapid mixed-methods evaluation. Health and Social Care Delivery Research , 10 (35) 10.3310/pqwc3425. Green open access

[thumbnail of 3041650.pdf]
Preview
Text
3041650.pdf - Published Version

Download (1MB) | Preview

Abstract

Background: There are over 15,000 care homes in England, with a total of approximately 450,000 beds. Most residents are older adults, some with dementia, and other residents are people of any age with physical or learning disabilities. Using pulse oximetry in care homes can help the monitoring and care of residents with COVID-19 and other conditions. Objectives: To explore the views of care home staff, and the NHS staff they interact with, with regard to using pulse oximetry with residents, as well as the NHS support provided for using pulse oximetry. Design: We carried out a rapid mixed-methods evaluation of care homes in England, comprising (1) scoping interviews with NHS leaders, care association directors and care home managers, engaging with relevant literature and co-designing the evaluation with a User Involvement Group; (2) an online survey of care homes; (3) interviews with care home managers and staff, and with NHS staff who support care homes, at six purposively selected sites; and (4) synthesis, reporting and dissemination. The study team undertook online meetings and a workshop to thematically synthesise findings, guided by a theoretical framework. Results: We obtained 232 survey responses from 15,362 care homes. Although this was a low (1.5%) response rate, it was expected given exceptional pressures on care home managers and staff at the time of the survey. We conducted 31 interviews at six case study sites. Pulse oximeters were used in many responding care homes before the pandemic and use of pulse oximeters widened during the pandemic. Pulse oximeters are reported by care home managers and staff to provide reassurance to residents and their families, as well as to staff. Using pulse oximeters was usually not challenging for staff and did not add to staff workload or stress levels. Additional support provided through the NHS COVID Oximetry @home programme was welcomed at the care homes receiving it; however, over half of survey respondents were unaware of the programme. In some cases, support from the NHS, including training, was sought but was not always available. Limitations: The survey response rate was low (1.5%) and so findings must be treated with caution. Fewer than the intended number of interviews were completed because of participant unavailability. Throughout the COVID-19 pandemic, care homes may have been asked to complete numerous other surveys etc., which may have contributed to these limitations. Owing to anonymity, the research team was unable to determine the range of survey respondents across location, financial budget or quality of care. Conclusions: Using pulse oximeters in care homes is considered by managers and staff to have been beneficial to care home residents. Ongoing training opportunities for care home staff in use of pulse oximeters would be beneficial. Escalation processes to and responses from NHS services could be more consistent, alongside promoting the NHS COVID Oximetry @home programme to care homes. Future research: Further research should include the experiences of care home residents and their families, as well as finding out more from an NHS perspective about interactions with care home staff. Research to investigate the cost-effectiveness of pulse oximetry in care homes, and of the NHS COVID Oximetry @home programme of support, would be desirable. Funding: This project was funded by the National Institute for Health and Care Research (NIHR) Health and Social Care Delivery Research programme and will be published in full in Health and Social Care Delivery Research; Vol. 10, No. 35. See the NIHR Journals Library website for further project information.

Type: Article
Title: Using pulse oximeters in care homes for residents with COVID-19 and other conditions: a rapid mixed-methods evaluation
Open access status: An open access version is available from UCL Discovery
DOI: 10.3310/pqwc3425
Publisher version: https://doi.org/10.3310/PQWC3425
Language: English
Additional information: Permission to reproduce material from a published report is covered by the creative commons licence http://creativecommons.org/licenses/by/4.0/
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Epidemiology and Health > Applied Health Research
URI: https://discovery.ucl.ac.uk/id/eprint/10161858
Downloads since deposit
118Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item