Experimental study on downward/opposed flame spread and extinction over electric wires in partial gravity environments.
Proceedings of the Combustion Institute
, 39
(3)
pp. 3785-3794.
10.1016/j.proci.2022.07.002.
Preview |
Text
PCI39_CNES-Partial-G-report_manuscript.pdf - Submitted Version Download (1MB) | Preview |
Abstract
Downward/opposed flame spread over laboratory wire samples under varied gravity conditions were investigated in the range from 0 G to 1 G. Reduced gravity experiments are conducted by parabolic flights of an airplane. Limiting oxygen concentrations (LOCs) and flame spread rates (Vf) are obtained as a function of gravity level, with oxygen concentration, forced flow velocity, and wire characteristics such as insulation thickness and core material as experimental variables. The samples used in this study consist of low-density polyethylene (LDPE) insulation over metallic cores. Copper (Cu) and nickel-chrome (NiCr) were selected as core materials. It is found that the effect of gravity on the insulation flammability varies with the thermal conductivity of the wire core; the LOCs of the Cu sample are less affected by gravity, while those of the NiCr sample decrease with decreasing gravity level. On the other hand, increase monotonically with increasing gravity level in the Cu sample, while of the NiCr sample show a peak value under the low gravity conditions. It is suggested that these differences in the response of LOCs and to the gravity level due to the difference in core materials are controlled by the fuel concentration in the reaction zone, which is a function of . It is also found that the molten LDPE produced during the flame spread process shows unique behaviors depending on the gravity levels and wire characteristics. Some characteristics of the dynamic motion of the molten LDPE during the flame spread process, such as deformation and dripping, are also summarized in this paper. The experimental data obtained in this study provide useful information on the flammability of materials in a partial gravity environment and will serve as a database for fire safety design in future space exploration.
Type: | Article |
---|---|
Title: | Experimental study on downward/opposed flame spread and extinction over electric wires in partial gravity environments |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.proci.2022.07.002 |
Publisher version: | https://doi.org/10.1016/j.proci.2022.07.002 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Spacecraft fire safety, Partial gravity, Parabolic flight experiment, Electric wire, Flame spread |