UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Deconstructing mastery in colorectal fluorescence angiography interpretation

Dalli, Jeffrey; Shanahan, Sarah; Hardy, Niall P; Chand, Manish; Hompes, Roel; Jayne, David; Ris, Frederic; ... Cahill, Ronan A; + view all (2022) Deconstructing mastery in colorectal fluorescence angiography interpretation. Surgical Endoscopy 10.1007/s00464-022-09299-3. (In press). Green open access

[thumbnail of Chand__DeconstructingMasteryInColorec.pdf]
Preview
Text
Chand__DeconstructingMasteryInColorec.pdf - Published Version

Download (1MB) | Preview

Abstract

INTRODUCTION: Indocyanine green fluorescence angiography (ICGFA) is commonly used in colorectal anastomotic practice with limited pre-training. Recent work has shown that there is considerable inconsistency in signal interpretation between surgeons with minimal or no experience versus those consciously invested in mastery of the technique. Here, we deconstruct the fluorescence signal patterns of expert-annotated surgical ICGFA videos to understand better their correlation and combine this with structured interviews to ascertain whether such interpretative capability is conscious or unconscious. METHODS: For fluorescence signal analysis, expert-annotated ICGFA videos (n = 24) were quantitatively interrogated using a boutique intensity tracker (IBM Research) to generate signal time plots. Such fluorescence intensity data were examined for inter-observer correlation (Intraclass Correlation Coefficients, ICC) at specific curve milestones: the maximum fluorescence signal (F_{max}), the times to both achieve this maximum (T_{max}), as well as half this maximum (T_{1/2max}) and the ratio between these (T_{1/2/Tmax}). ormal tele-interview with contributing experts (n = 6) was conducted with the narrative transcripts being thematically mapped, plotted, and qualitatively analyzed. RESULTS: Correlation by mathematical measures was excellent (ICC0.9–1.0) for F_{max}, T_{max}, and T_{1/2max} (0.95, 0.938, and 0.925, respectively) and moderate (0.5–0.75) for T_{1/2/Tmax} (0.729). While all experts narrated a deliberate viewing strategy, their specific dynamic signal appreciation differed in the manner of description. CONCLUSION: Expert ICGFA users demonstrate high correlation in mathematical measures of their signal interpretation although do so tacitly. Computational quantification of expert behavior can help develop the necessary lexicon and training sets as well as computer vision methodology to better exploit ICGFA technology.

Type: Article
Title: Deconstructing mastery in colorectal fluorescence angiography interpretation
Location: Germany
Open access status: An open access version is available from UCL Discovery
DOI: 10.1007/s00464-022-09299-3
Publisher version: https://doi.org/10.1007/s00464-022-09299-3
Language: English
Additional information: © 2022 Springer Nature Switzerland AG. This article is licensed under a Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/).
Keywords: Indocyanine green, Fluorescence, Angiography, Digital, Quantitative
UCL classification: UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
URI: https://discovery.ucl.ac.uk/id/eprint/10149858
Downloads since deposit
21Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item