Multiple-Breath Washout Outcome Measures in Adults with Bronchiectasis

O'Neill, Katherine; Lakshmipathy, Gokul R; Neely, Curtis; Cosgrove, Denise; Ferguson, Kathryn; McLeese, Rebecca; Hill, Adam T; ... Bradley, Judy M; + view all (2022) Multiple-Breath Washout Outcome Measures in Adults with Bronchiectasis. Annals of the American Thoracic Society , 19 (9) pp. 1489-1497. 10.1513/AnnalsATS.202006-584OC. Green open access

[thumbnail of Hurst_FINAL_CLEAN_revision 2.0_Multiple Breath Washout outcome measures in adults with bronchiectasis_061221_KON, JB,SE,RM.pdf]
Preview
Text
Hurst_FINAL_CLEAN_revision 2.0_Multiple Breath Washout outcome measures in adults with bronchiectasis_061221_KON, JB,SE,RM.pdf

Download (325kB) | Preview

Abstract

RATIONALE: Lung Clearance index (LCI) has good intra-visit repeatability with better sensitivity in detecting lung disease on CT scan compared to Forced Expiratory Volume in 1 second (FEV1) in adults with bronchiectasis. Alternative multiple breath washout (MBW) parameters have not been systematically studied in bronchiectasis. OBJECTIVES: To determine the validity, repeatability, sensitivity, specificity and feasibility of standard LCI (LCI2.5), shortened LCI (LCI5.0), ScondVT and SacinVT in a cross-sectional observational cohort of adults with bronchiectasis. METHODS: Cross-sectional MBN2W data (Exhalyzer® D) from 132 patients with bronchiectasis across 5 UK centres (Bronch-UK Clinimetrics study) and 88 healthy controls were analysed. RESULTS: Within test repeatability (mean CV%) was <5% for both LCI2.5 and LCI5.0 in patients with bronchiectasis and there was no difference in mean CV% in LCI2.5 and LCI5.0 in patients with bronchiectasis compared to healthy volunteers. Moderate strength correlations were seen between FEV1 and LCI2.5 (r=-0.54), LCI5.0 (r=-0.53), ScondVT (r=-0.35) and SacinVT z-scores (r=-0.38). The proportion of subjects with abnormal MBW (>2 z-score) but normal FEV1 (<-2 z-score) was 42% (LCI2.5) and 36% (LCI5.0). Overall results from the receiver operator characteristic curve (AUCROC) indicated that LCI2.5 had greatest combined sensitivity and specificity to discriminate between bronchiectasis and control subjects, followed by LCI5.0, FEV1 and ScondVT z-scores. There was a 57% time saving with LCI5.0. CONCLUSIONS: LCI2.5 and LCI5.0 had good within test repeatability and superior sensitivity compared with spirometry measures, in differentiating between health and bronchiectasis disease. LCI5.0 is shorter and more feasible than LCI2.5. Clinical trial registered with ClinicalTrials.gov (NCT02468271).

Type: Article
Title: Multiple-Breath Washout Outcome Measures in Adults with Bronchiectasis
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1513/AnnalsATS.202006-584OC
Publisher version: https://doi.org/10.1513/AnnalsATS.202006-584OC
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Respiratory Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10148329
Downloads since deposit
12Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item