Mota, AM;
Clarkson, MJ;
Almeida, P;
Matela, N;
(2020)
Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering.
Journal of Imaging
, 6
(7)
, Article 64. 10.3390/JIMAGING6070064.
Preview |
Text
jimaging-06-00064-v2.pdf - Published Version Download (4MB) | Preview |
Abstract
3D volume rendering may represent a complementary option in the visualization of Digital Breast Tomosynthesis (DBT) examinations by providing an understanding of the underlying data at once. Rendering parameters directly influence the quality of rendered images. The purpose of this work is to study the influence of two of these parameters (voxel dimension in z direction and sampling distance) on DBT rendered data. Both parameters were studied with a real phantom and one clinical DBT data set. The voxel size was changed from 0.085 × 0.085 × 1.0 mm3 to 0.085 × 0.085 × 0.085 mm3 using ten interpolation functions available in the Visualization Toolkit library (VTK) and several sampling distance values were evaluated. The results were investigated at 90ºusing volume rendering visualization with composite technique. For phantom quantitative analysis, degree of smoothness, contrast-to-noise ratio, and full width at half maximum of a Gaussian curve fitted to the profile of one disk were used. Additionally, the time required for each visualization was also recorded. Hamming interpolation function presented the best compromise in image quality. The sampling distance values that showed a better balance between time and image quality were 0.025 mm and 0.05 mm. With the appropriate rendering parameters, a significant improvement in rendered images was achieved.
Type: | Article |
---|---|
Title: | Optimization of Breast Tomosynthesis Visualization through 3D Volume Rendering |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.3390/JIMAGING6070064 |
Publisher version: | http://dx.doi.org/10.3390/JIMAGING6070064 |
Language: | English |
Additional information: | This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited |
Keywords: | breast tomosynthesis; visualization; volume rendering |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng |
URI: | https://discovery.ucl.ac.uk/id/eprint/10112207 |