Rogers, J;
Sherwood, V;
Wayte, SC;
Duffy, JA;
Manolopoulos, S;
(2020)
Quantification and correction of distortion in diffusion-weighted MRI at 1.5 and 3 T in a muscle-invasive bladder cancer phantom for radiotherapy planning.
British Journal of Radiology
, 93
(1114)
, Article 20190710. 10.1259/bjr.20190710.
Preview |
Text
Manolopoulos_DWI MRI geom distortion eval BJR 93 (2020) 20190710 Rogers et al.pdf - Published Version Download (307kB) | Preview |
Abstract
OBJECTIVE: Limited visibility of post-resection muscle-invasive bladder cancer (MIBC) on CT hinders radiotherapy dose escalation of the residual tumour. Diffusion-weighted MRI (DW-MRI) visualises areas of high tumour burden and is increasingly used within diagnosis and as a biomarker for cancer. DW-MRI could, therefore, facilitate dose escalation, potentially via dose-painting and/or accommodating response. However, the distortion inherent in DW-MRI could limit geometric accuracy. Therefore, this study aims to quantify DW-MRI distortion via imaging of a bladder phantom. METHODS: A phantom was designed to mimic MIBC and imaged using CT, DW-MRI and T2W-MRI. Fiducial marker locations were compared across modalities and publicly available software was assessed for correction of magnetic susceptibility-related distortion. RESULTS: Fiducial marker locations on CT and T2W-MRI agreed within 1.2 mm at 3 T and 1.8 mm at 1.5 T. The greatest discrepancy between CT and apparent diffusion coefficient (ADC) maps was 6.3 mm at 3 T, reducing to 1.8 mm when corrected for distortion. At 1.5 T, these values were 3.9 mm and 1.7 mm, respectively. CONCLUSIONS: Geometric distortion in DW-MRI of a model bladder was initially >6 mm at 3 T and >3 mm at 1.5 T; however, established correction methods reduced this to <2 mm in both cases. ADVANCES IN KNOWLEDGE: A phantom designed to mimic MIBC has been produced and used to show distortion in DW-MRI can be sufficiently mitigated for incorporation into the radiotherapy pathway. Further investigation is therefore warranted to enable individually adaptive image-guided radiotherapy of MIBC based upon DW-MRI.
Type: | Article |
---|---|
Title: | Quantification and correction of distortion in diffusion-weighted MRI at 1.5 and 3 T in a muscle-invasive bladder cancer phantom for radiotherapy planning |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1259/bjr.20190710 |
Publisher version: | https://doi.org/10.1002/celc.201900815 |
Language: | English |
Additional information: | This version is the version of record. For information on re-use, please refer to the publisher’s terms and conditions. |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng |
URI: | https://discovery.ucl.ac.uk/id/eprint/10111245 |
Archive Staff Only
View Item |