Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis

Goodlad, C; George, S; Sandoval, S; Mepham, S; Parekh, G; Eberl, M; Topley, N; (2020) Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis. Kidney International , 97 (6) pp. 1253-1259. 10.1016/j.kint.2020.01.044. Green open access

[thumbnail of Davenport_Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis_AAM.pdf]
Preview
Text
Davenport_Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis_AAM.pdf - Accepted Version

Download (285kB) | Preview

Abstract

Peritonitis is the commonest complication of peritoneal dialysis and a major reason for treatment failure. Current diagnosis is based on clinical symptoms, cloudy effluent and a dialysate white cell count (over 100 cells/μl). A rapid point-of-care diagnostic test would accelerate diagnosis and potentially improve outcomes from infection. Here, in a clinical audit project, we used PERiPLEX®, a point-of-care device which detects when levels of matrix metalloproteinase-8 and interleukin-6 are elevated above a threshold within minutes in dialysis effluent, to assess whether it could confirm or exclude peritonitis in 107 patients undergoing peritoneal dialysis. Mean patient age was 64.6 years with a median duration of peritoneal dialysis of 13.3 months (interquartile range 6.3 – 33.5 months). Presence of peritonitis was confirmed by clinical criteria. There were 49 positive tests of which 41 patients had peritonitis, three had other causes of intra-peritoneal inflammation, three had severe urosepsis and two patients required no treatment. Fifty-eight tests were negative with one patient having a false negative result. The positive predictive value of the test was 83.7% (95% confidence interval 72.8 – 90.8) and the negative predictive value was 98.3% (89.1 – 99.8). Sensitivity and specificity were 97.6% (87.4 – 99.9) and 87.7% (77.2 – 94.5) respectively. Thus, PERiPLEX® could be used as a rapid point-of-care test that can aid the diagnosis or exclusion of peritonitis with a high negative predictive value.

Type: Article
Title: Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.kint.2020.01.044
Publisher version: https://doi.org/10.1016/j.kint.2020.01.044
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions.
Keywords: biomarkers, infection diagnosis, peritoneal dialysis, peritonitis, point-of-care
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10097115
Downloads since deposit
Loading...
228Downloads
Download activity - last month
Loading...
Download activity - last 12 months
Loading...
Downloads by country - last 12 months
1.United States
11
2.United Kingdom
2
3.Indonesia
2
4.China
2
5.Israel
1
6.South Africa
1
7.Saudi Arabia
1
8.Russian Federation
1
9.Singapore
1
10.Thailand
1

Archive Staff Only

View Item View Item