UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Quantitative characterization of three-dimensional pore structure in hardened cement paste using X-ray microtomography combined with centrifuge driven metal alloy intrusion

Qian, R; Zhang, Y; Liu, C; Yang, L; Liu, G; She, W; (2018) Quantitative characterization of three-dimensional pore structure in hardened cement paste using X-ray microtomography combined with centrifuge driven metal alloy intrusion. Materials Characterization , 145 pp. 277-283. 10.1016/j.matchar.2018.08.047. Green open access

[thumbnail of Quantitative characterization.pdf]
Preview
Text
Quantitative characterization.pdf - Accepted Version

Download (1MB) | Preview

Abstract

In this paper, a centrifuge device is proposed to facilitate the intrusion of a low-melting point metal alloy into the pore space of hardened cement paste. X-ray microtomography is combined with metal centrifugation porosimetry (MCP) to quantitatively investigate 3D pore structure. The low-melting-point metal alloy is melted and introduced into pore space in pastes with water cement ratio of 0.5 and 1.0 at a temperature of 65 °C. 3D pore structure is quantitatively analyzed by X-ray microtomography after the molten metal alloy has been consolidated. A new threshold value segmentation method for pore space was proposed using conversion coefficient on region of interest (ROI). Porosity and pore size distribution are tested by MCP and compared with the results based on mercury intrusion porosimetry (MIP). The results show that the contrast between pore space and solid phase in the X-ray microtomography device image is improved. The total porosity obtained by MCP was found to be consistent with the results obtained by MIP.

Type: Article
Title: Quantitative characterization of three-dimensional pore structure in hardened cement paste using X-ray microtomography combined with centrifuge driven metal alloy intrusion
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.matchar.2018.08.047
Publisher version: https://doi.org/10.1016/j.matchar.2018.08.047
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: X-ray microtomography, Porous material, 3D pore structure, Quantitative characterization, Cement
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10092558