Cerebellar transcranial magnetic stimulation: The role of coil type from distinct manufacturers.
Brain Stimulation
10.1016/j.brs.2019.09.005.
(In press).
Preview |
Text
Rothwell_cbi_coils_manu2_ds.pdf - Accepted Version Download (570kB) | Preview |
Abstract
BACKGROUND: Stimulating the cerebellum with transcranial magnetic stimulation is often perceived as uncomfortable. No study has systematically tested which coil design can effectively trigger a cerebellar response with the least discomfort. OBJECTIVE: To determine the relationship between perceived discomfort and effectiveness of cerebellar stimulation using different coils: MagStim (70 mm, 110 mm-coated, 110-uncoated), MagVenture and Deymed. METHODS: Using the cerebellar-brain inhibition (CBI) protocol, we conducted a CBI recruitment curve with respect to each participant's maximum tolerated-stimulus intensity (MTI) to assess how effective each coil was at activating the cerebellum. RESULTS: Only the Deymed double-cone coil elicited CBI at low intensities (-20% MTI). At the MTI, the MagStim (110 mm coated/uncoated) and Deymed coils produced reliable CBI, whereas no CBI was found with the MagVenture coil. CONCLUSION: s: The Deymed double-cone coil was most effective at cerebellar stimulation at tolerable intensities. These results can guide coil selection and stimulation parameters when designing cerebellar TMS studies.
Type: | Article |
---|---|
Title: | Cerebellar transcranial magnetic stimulation: The role of coil type from distinct manufacturers |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.brs.2019.09.005 |
Publisher version: | https://doi.org/10.1016/j.brs.2019.09.005 |
Language: | English |
Additional information: | This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
Keywords: | Cerebellar-M1, Cerebellum, Connectivity, Transcranial magnetic stimulation |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Clinical and Movement Neurosciences |