UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI

Battiston, M; Schneider, T; Grussu, F; Yiannakas, MC; Prados, F; De Angelis, F; Gandini Wheeler-Kingshott, CAM; (2019) Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI. Magnetic Resonance in Medicine , 82 (3) pp. 1025-1040. 10.1002/mrm.27792. Green open access

[thumbnail of Battiston_MRM19_RPS.pdf]
Preview
Text
Battiston_MRM19_RPS.pdf - Accepted Version

Download (3MB) | Preview

Abstract

PURPOSE: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain. THEORY AND METHODS: The theory of steady-state MT in the fast-exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time ( T 2 B ). A sequence that allows sampling of the signal during steady-state MT saturation is used to perform BPF mapping with a 10-min-long fully echo planar imaging-based MRI protocol, including inversion recovery T1 mapping and B1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single-slice full qMT reference acquisition. RESULTS: BPF measurements are in agreement with literature values using off-resonance MT, with average BPF of 0.114(0.100-0.128) in white matter and 0.068(0.054-0.085) in gray matter. Median voxel-wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81-0.85) and 0.013(0.11-0.16). Bland-Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions. CONCLUSION: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.

Type: Article
Title: Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1002/mrm.27792
Publisher version: https://doi.org/10.1002/mrm.27792
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: 2-pool model, EPI, bound pool fraction, magnetization transfer, myelin, quantitative steady-state
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Neuroinflammation
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10075116
Downloads since deposit
156Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item