Zhou, F-L;
Wu, H;
McHugh, DJ;
Wimpenny, I;
Zhang, X;
Gough, JE;
Hubbard Cristinacce, PL;
(2019)
Co-electrospraying of tumour cell mimicking hollow polymeric microspheres for diffusion magnetic resonance imaging.
Materials Science and Engineering: C
, 101
pp. 217-227.
10.1016/j.msec.2019.03.062.
Preview |
Text
MSEC_2018_3180_accepted%20version%202019.pdf - Accepted Version Download (6MB) | Preview |
Abstract
Diffusion magnetic resonance imaging (dMRI) is considered as a useful tool to study solid tumours. However, the interpretation of dMRI signal and validation of quantitative measurements of is challenging. One way to address these challenges is by using a standard reference material that can mimic tumour cell microstructure. There is a growing interest in using hollow polymeric microspheres, mainly prepared by multiple steps, as mimics of cells in healthy and diseased tissue. The present work reports on tumour cell-mimicking materials composed of hollow microspheres for application as a standard material in dMRI. These microspheres were prepared via one-step co-electrospraying process. The shell material was poly(d,l-lactic-co-glycolic acid) (PLGA) polymers with different molecule weights and/or ratios of glycolic acid-to-lactic, while the core was polyethylene glycol (PEG) or ethylene glycol. The resultant co-electrosprayed products were characterised by optical microscopy, scanning electron microscopy (SEM) and synchrotron X-ray micro-CT. These products were found to have variable structures and morphologies, e.g. from spherical particles with/without surface hole, through beaded fibres to smooth fibres, which mainly depend on PLGA composition and core materials. Only the shell material of PLGA polymer with ester terminated, Mw 50,000-75,000 g mol-1, and lactide:glycolide 85:15 formed hollow microspheres via the co-electrospraying process using the core material of 8 wt% PEG/chloroform as the core. A water-filled test object (or phantom) was designed and constructed from samples of the material generated from co-electrosprayed PLGA microspheres and tested on a 7 T MRI scanner. The preliminary MRI results provide evidence that hollow PLGA microspheres can restrict/hinder water diffusion as cells do in tumour tissue, implying that the phantom may be suitable for use as a quantitative validation and calibration tool for dMRI.
Type: | Article |
---|---|
Title: | Co-electrospraying of tumour cell mimicking hollow polymeric microspheres for diffusion magnetic resonance imaging |
Location: | Netherlands |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.msec.2019.03.062 |
Publisher version: | https://doi.org/10.1016/j.msec.2019.03.062 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Co-electrospraying, Diffusion magnetic resonance imaging, Hollow microspheres, Phantom, Tumour cells |