Compressive sensing in electrical impedance tomography for breathing monitoring

Shiraz, A; Khodadad, D; Nordebo, S; Yerworth, R; Frerichs, I; van Kaam, A; Kallio, M; ... Demosthenous, A; + view all (2019) Compressive sensing in electrical impedance tomography for breathing monitoring. Physiological Measurement , 40 (3) , Article 034010. 10.1088/1361-6579/ab0daa. Green open access

[thumbnail of Shiraz+et+al_2019_Physiol._Meas._10.1088_1361-6579_ab0daa.pdf]
Preview
Text
Shiraz+et+al_2019_Physiol._Meas._10.1088_1361-6579_ab0daa.pdf - Accepted Version

Download (793kB) | Preview

Abstract

OBJECTIVE: Continuous functional thorax monitoring using EIT has been extensively researched. A limiting factor in high temporal resolution, three dimensional, and fast EIT is the handling of the volume of raw impedance data produced for transmission and storage. Owing to the periodicity of breathing that may be reflected in EIT boundary measurements, data dimensionality may be reduced efficiently at the time of sampling using compressed sensing techniques. APPROACH: Measurements using a 32-electrode 48-frame-per-second EIT system from 30 neonates were post-processed to simulate random demodulation acquisition method on 2000 frames for compression ratios (CRs) ranging from 2-100. Sparse reconstruction was performed by solving the basis pursuit problem using SPGL1 package. The global impedance data was used in the subsequent studies. The signal to noise ratio (SNR) for the entire frequency band (0 Hz - 24 Hz) and three local frequency bands were analysed. A breath detection algorithm was applied to traces and the subsequent error-rates were calculated while considering the outcome of the algorithm applied to a down-sampled and linearly interpolated version of the traces as the baseline. MAIN RESULTS: SNR degradation was proportional with CR. The mean degradation for 0 Hz - 8 Hz was below ~15 dB for all CRs. The error-rates in the outcome of the breath detection algorithm in the case of decompressed traces were lower than those of the associated down-sampled traces for CR≥25, corresponding to sub-Nyquist rate for breathing. For instance, the mean error-rate associated with CR = 50 was ~60% lower than that of the corresponding down-sampled traces. SIGNIFICANCE: To the best of our knowledge, no other study has evaluated compressive sensing on boundary impedance data in EIT. While further research should be directed at optimising the acquisition and decompression techniques for this application, this contribution serves as the baseline for future efforts.

Type: Article
Title: Compressive sensing in electrical impedance tomography for breathing monitoring
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6579/ab0daa
Publisher version: https://doi.org/10.1088/1361-6579/ab0daa
Language: English
Additional information: © 2018 Institute of Physics and Engineering in Medicine. As the Version of Record of this article is going to be/has been published on a gold open access basis under a CC BY 3.0 licence, this Accepted Manuscript is available for reuse under a CC BY 3.0 licence immediately. Everyone is permitted to use all or part of the original content in this article, provided that they adhere to all the terms of the licence https://creativecommons.org/ licences/by/3.0. Although reasonable endeavours have been taken to obtain all necessary permissions from third parties to include their copyrighted content within this article, their full citation and copyright line may not be present in this Accepted Manuscript version. Before using any content from this article, please refer to the Version of Record on IOPscience once published for full citation and copyright details, as permissions may be required. All third party content is fully copyright protected and is not published on a gold open access basis under a CC BY licence, unless that is specifically stated in the figure caption in the Version of Record.
Keywords: breath detection, compressive sensing, electrical impedance tomography
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10070042
Downloads since deposit
93Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item