Sinha, S;
Fok, M;
Davenport, A;
Banga, N;
Lindsey, B;
Fernando, B;
Forman, CJ;
(2018)
Use of the embedded peritoneal dialysis catheter.
Annals of The Royal College of Surgeons of England
, 100
(7)
pp. 534-544.
10.1308/rcsann.2018.0088.
Preview |
Text
Use of the embedded peritoneal dialysis catheter.pdf - Published Version Download (652kB) | Preview |
Abstract
Introduction The use of embedded peritoneal dialysis (PD) catheters is purported to offer numerous benefits over standard placement. However, the optimum period of embedment and the effect of prolonged embedment on subsequent catheter function remain unclear. Methods This retrospective observational study looked at adult patients undergoing embedded PD catheter insertion in a large tertiary referral centre in the UK. Possible predictors for catheter non-function at externalisation were investigated. These included patient factors (age, sex, diabetic status, body mass index, ethnicity, smoking status, previous surgery, estimated glomerular filtration rate), procedural factors (modality of surgery, concurrent surgical procedure), duration of catheter embedment and catheter damage at externalisation. Outcomes examined were proportion of catheters functioning after externalisation, futile placement rate, surgical reintervention rate, infectious complication rate and proportion of externalised catheters lost owing to malfunction. Results Sixty-six catheters were embedded and two-thirds (n=47, 63.6%) were externalised after a median embedment period of 39.4 weeks. Of these, 25 (53.2%) functioned on externalisation. Fourteen (63.6%) of the 22 non-functioning catheters were salvaged. The overall utilisation of PD was 34/47 (72.3%) and the futile placement rate was 12.1%. Over half of the externalised catheters (n=27, 57.4%) were lost directly as a result of catheter related complications, with a median survival time of 39.4 weeks. In adjusted analysis, increasing embedment duration was significantly predictive of catheter non-function at externalisation (adjusted odds ratio: 0.957, 95% confidence interval [CI]: 0.929-0.985, p=0.003) while subsequent catheter loss was highly dependent on catheter function at externalisation (hazard ratio: 0.258, 95% CI: 0.112-0.594, p=0.001). Conclusions Prolonged embedment of PD catheters is associated with a significantly higher likelihood of catheter dysfunction following externalisation, which is in turn associated with subsequent catheter loss. We have discontinued the use of this technique in our unit.
Type: | Article |
---|---|
Title: | Use of the embedded peritoneal dialysis catheter |
Location: | England |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1308/rcsann.2018.0088 |
Publisher version: | https://doi.org/10.1308/rcsann.2018.0088 |
Language: | English |
Additional information: | This version is the version of record. For information on re-use, please refer to the publisher’s terms and conditions. |
Keywords: | Catheter, Moncrief-Popovich, Peritoneal dialysis, Adult, Aged, Catheterization, Catheters, Indwelling, Female, Humans, Male, Middle Aged, Peritoneal Dialysis, Retrospective Studies, Risk Factors, Survival Analysis, United Kingdom |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine |
URI: | https://discovery.ucl.ac.uk/id/eprint/10060734 |




Archive Staff Only
![]() |
View Item |