Dravida, S;
Noah, JA;
Zhang, X;
Hirsch, J;
(2018)
Comparison of Oxyhemoglobin and Deoxyhemoglobin Signal Reliability With and Without Global Mean Removal for Digit Manipulation Motor Tasks.
Neurophotonics
, 5
(1)
, Article 011006. 10.1117/1.NPh.5.1.011006.
Preview |
Text
011006_1.pdf - Published Version Download (5MB) | Preview |
Abstract
Functional near-infrared spectroscopy (fNIRS) could be well suited for clinical use, such as measuring neural activity before and after treatment; however, reliability and specificity of fNIRS signals must be ensured so that differences can be attributed to the intervention. This study compared the test–retest and longitudinal reliability of oxyhemoglobin and deoxyhemoglobin signals before and after spatial filtering. In the test–retest experiment, 14 participants were scanned on 2 days while performing four right-handed digit-manipulation tasks. Group results revealed greater test–retest reliability for oxyhemoglobin than deoxyhemoglobin signals and greater spatial specificity for the deoxyhemoglobin signals. To further characterize reliability, a longitudinal experiment was conducted in which two participants repeated the same motor tasks for 10 days. Beta values from the two tasks with the lowest and highest test–retest reliability, respectively, in the spatially filtered deoxyhemoglobin signal are reported as representative findings. Both test–retest and longitudinal methods confirmed that task and signal type influence reliability. Oxyhemoglobin signals were more reliable overall than deoxyhemoglobin, and removal of the global mean reduced reliability of both signals. Findings are consistent with the suggestion that systemic components most prevalent in the oxyhemoglobin signal may inflate reliability relative to the deoxyhemoglobin signal, which is less influenced by systemic factors.
Type: | Article |
---|---|
Title: | Comparison of Oxyhemoglobin and Deoxyhemoglobin Signal Reliability With and Without Global Mean Removal for Digit Manipulation Motor Tasks |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1117/1.NPh.5.1.011006 |
Publisher version: | https://doi.org/10.1117/1.NPh.5.1.011006 |
Language: | English |
Additional information: | Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
Keywords: | reliability, functional near-infrared spectroscopy, finger-tapping, global mean |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng |
URI: | https://discovery.ucl.ac.uk/id/eprint/10060226 |




Archive Staff Only
![]() |
View Item |