Acceptability, Accuracy and Safety of Disposable Transnasal Capsule Endoscopy for Barrett’s Esophagus Screening.
Clinical Gastroenterology and Hepatology
10.1016/j.cgh.2018.07.019.
(In press).
Preview |
Text
Sami_Acceptability, Accuracy and Safety of Disposable Transnasal Capsule Endoscopy for Barrett's Esophagus Screening_AAM.pdf - Accepted Version Download (3MB) | Preview |
Abstract
BACKGROUND & AIMS: Screening for Barrett's esophagus (BE) with conventional esophagogastroduodenoscopy (C-EGD) is expensive. We assessed the performance of a clinic-based, single use transnasal capsule endoscope (EG Scan II) for the detection of BE, compared to C-EGD as the reference standard. METHODS: We performed a prospective multicenter cohort study of patients with and without BE recruited from 3 referral centers (1 in the United States and 2 in the United Kingdom). Of 200 consenting participants, 178 (89%) completed both procedures (11% failed EG Scan due to the inability to intubate the nasopharynx). The mean age of participants was 57.9 years and 67% were male. The prevalence of BE was 53%. All subjects underwent the 2 procedures on the same day, performed by blinded endoscopists. Patients completed preference and validated tolerability (10-point visual analogue scale [VAS]) questionnaires within 14 days of the procedures. RESULTS: A higher proportion of patients preferred the EG Scan (54.2%) vs the C-EGD (16.7%) (P<.001) and the EG Scan had a higher VAS score (7.2) vs the C-EGD (6.4) (P=.0004). No serious adverse events occurred. The EG Scan identified any length BE with a sensitivity value of 0.90 (95% CI, 0.83-0.96) and a specificity value of 0.91 (95% CI, 0.82-0.96). The EG Scan identified long segment BE with a sensitivity value of 0.95 and short segment BE with a sensitivity values of 0.87. CONCLUSION: In a prospective study, we found the EG Scan to be safe and to detect BE with higher than 90% sensitivity and specificity. A higher proportion of patients preferred the EG Scan to C-EGD. This device might be used as a clinic-based tool to screen populations at risk for BE. ISRCTN registry identifier: 70595405; ClinicalTrials.gov no: NCT02066233.
Type: | Article |
---|---|
Title: | Acceptability, Accuracy and Safety of Disposable Transnasal Capsule Endoscopy for Barrett’s Esophagus Screening |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.cgh.2018.07.019 |
Publisher version: | https://doi.org/10.1016/j.cgh.2018.07.019 |
Language: | English |
Additional information: | © 2018 by the AGA Institute. This is an Open Access article published under the terms of The Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
Keywords: | Esophageal adenocarcinoma, imaging, office, portable, reflux |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci |
URI: | https://discovery.ucl.ac.uk/id/eprint/10055162 |
Archive Staff Only
![]() |
View Item |