Optimized breath detection algorithm in electrical impedance tomography

Khodadad, D; Nordebo, S; Mueller, B; Waldmann, AD; Yerworth, R; Becher, T; Frerichs, I; ... Bayford, RH; + view all (2018) Optimized breath detection algorithm in electrical impedance tomography. Physiological Measurement , 39 (9) , Article 094001. 10.1088/1361-6579/aad7e6. Green open access

[thumbnail of O. B. D. A. in EIT_V9_Accepted Revision 1_DK.pdf]
Preview
Text
O. B. D. A. in EIT_V9_Accepted Revision 1_DK.pdf - Accepted Version

Download (1MB) | Preview

Abstract

OBJECTIVE: This paper defines a method for optimizing the breath delineation algorithms used in Electrical Impedance Tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern. APPROACH: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project. MAIN RESULTS: Three different algorithms are proposed that are improving the breath detector performance by adding conditions on 1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, 2) minimum tidal impedance amplitude and 3) minimum tidal breath rate obtained from Time-Frequency (TF) analysis. As a baseline the zero crossing algorithm has been used with some default parameters based on the Swisstom EIT device. SIGNIFICANCE: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the Receiver Operating Characterics (ROC). This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.

Type: Article
Title: Optimized breath detection algorithm in electrical impedance tomography
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1088/1361-6579/aad7e6
Publisher version: https://doi.org/10.1088/1361-6579/aad7e6
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Electrical Impedance Tomography, Receiver Operating Characteristics, breath detection, global optimisation, inspiration, lung imaging, respiratory system
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Electronic and Electrical Eng
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10054486
Downloads since deposit
Loading...
169Downloads
Download activity - last month
Loading...
Download activity - last 12 months
Loading...
Downloads by country - last 12 months
Loading...

Archive Staff Only

View Item View Item