UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Measurement of Muscle Strength in Haemodialysis Patients by Pinch and Hand Grip Strength and Comparison to Lean Body Mass Measured by Multifrequency Bio-Electrical Impedance

Omichi, Y; Srivareerat, M; Panorchan, K; Greenhall, GHB; Gupta, S; Davenport, A; (2016) Measurement of Muscle Strength in Haemodialysis Patients by Pinch and Hand Grip Strength and Comparison to Lean Body Mass Measured by Multifrequency Bio-Electrical Impedance. Annals of Nutrition and Metabolism , 68 (4) pp. 268-275. 10.1159/000447023. Green open access

[thumbnail of Davenport_RevisedAnnalsNutrMetabHGSandPSapril21.pdf]
Preview
Text
Davenport_RevisedAnnalsNutrMetabHGSandPSapril21.pdf - Accepted Version

Download (262kB) | Preview

Abstract

Background: Muscle weakness is a risk factor for mortality in haemodialysis (HD) patients; we wished to determine whether measuring the composition of the arm with bioimpedance was associated with arm muscle strength. Methods: We measured pinch strength (PS) and hand grip strength (HGS) in 250 adult HD patients with corresponding post-dialysis multifrequency bioelectrical assessments with segmental body analysis. Results: Mean age 64.0 ± 15.6, 66% male and 45.6% diabetic. The maximum HGS in the dominant or non-fistula arm was 18.9 ± 9.2 kg and PS 4.09 ± 1.96 kg respectively, with a correlation of r = 0.80, p < 0.001. HGS was associated with body cell mass (β 0.37, p < 0.001) and PS with appendicular muscle mass (β 0.06, p < 0.001). Both HGS and PS were independently associated with the ratio of extracellular water (ECW) to total body water (TBW); β -139.5, p = 0.024, β -44.8, p < 0.001 in the arm. The presence of an arterio-venous fistula increased the ECW/TBW ratio in the arm from 0.383 ± 0.009 to 0.390 ± 0.012, p < 0.05. Conclusion: Muscle strength measured by HGS and PS was associated with both markers of whole body and segmental body composition within the arm, particularly ECW/TBW. Bioimpedance measurements and assessment of muscle strength should be measured in the non-fistula arm.

Type: Article
Title: Measurement of Muscle Strength in Haemodialysis Patients by Pinch and Hand Grip Strength and Comparison to Lean Body Mass Measured by Multifrequency Bio-Electrical Impedance
Open access status: An open access version is available from UCL Discovery
DOI: 10.1159/000447023
Publisher version: https://doi.org/10.1159/000447023
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10053137
Downloads since deposit
Loading...
336Downloads
Download activity - last month
Loading...
Download activity - last 12 months
Loading...
Downloads by country - last 12 months
Loading...

Archive Staff Only

View Item View Item