Faulkner, M;
Hannan, S;
Aristovich, K;
Avery, J;
Holder, D;
(2018)
Feasibility of imaging evoked activity throughout the rat brain using electrical impedance tomography.
Neuroimage
, 178
pp. 1-10.
10.1016/j.neuroimage.2018.05.022.
Preview |
Text
1-s2.0-S1053811918304270-main.pdf - Published Version Download (1MB) | Preview |
Abstract
Electrical Impedance Tomography (EIT) is an emerging technique which has been used to image evoked activity during whisker displacement in the cortex of an anaesthetised rat with a spatiotemporal resolution of 200 μm and 2 ms. The aim of this work was to extend EIT to image not only from the cortex but also from deeper structures active in somatosensory processing, specifically the ventral posterolateral (VPL) nucleus of the thalamus. The direct response in the cortex and VPL following 2 Hz forepaw stimulation were quantified using a 57-channel epicortical electrode array and a 16-channel depth electrode. Impedance changes of -0.16 ± 0.08% at 12.9 ± 1.4 ms and -0.41 ± 0.14% at 8.8±1.9 ms were recorded from the cortex and VPL respectively. For imaging purposes, two 57-channel epicortical electrode arrays were used with one placed on each hemisphere of the rat brain. Despite using parameters optimised toward measuring thalamic activity and undertaking extensive averaging, reconstructed activity was constrained to the cortical somatosensory forepaw region and no significant activity at a depth greater than 1.6 mm below the surface of the cortex could be reconstructed. An evaluation of the depth sensitivity of EIT was investigated in simulations using estimates of the conductivity change and noise levels derived from experiments. These indicate that EIT imaging with epicortical electrodes is limited to activity occurring 2.5 mm below the surface of the cortex. This depth includes the hippocampus and so EIT has the potential to image activity, such as epilepsy, originating from this structure. To image deeper activity, however, alternative methods such as the additional implementation of depth electrodes will be required to gain the necessary depth resolution.
Type: | Article |
---|---|
Title: | Feasibility of imaging evoked activity throughout the rat brain using electrical impedance tomography |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.neuroimage.2018.05.022 |
Publisher version: | https://doi.org/10.1016/j.neuroimage.2018.05.022 |
Language: | English |
Additional information: | This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
Keywords: | Cortex, Electrical impedance tomography, Evoked potentials, Fast neural EIT, Rat, VPL |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Department of Neuromuscular Diseases UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng |
URI: | https://discovery.ucl.ac.uk/id/eprint/10050738 |
Archive Staff Only
View Item |