Chen, C;
Ling, H;
Zhai, Z;
Li, Y;
Yang, F;
Han, F;
Wei, S;
(2018)
Thermal performance of an active-passive ventilation wall with phase change material in solar greenhouses.
Applied Energy
, 216
pp. 602-612.
10.1016/j.apenergy.2018.02.130.
Preview |
Text
Wei_Final Manuscript_solar greenhouses.pdf - Accepted Version Download (3MB) | Preview |
Abstract
© 2018 Elsevier Ltd Using phase change material (PCM) in the north wall of solar greenhouses has been recommended as an efficient solution for promoting their indoor thermal environment. In this type of walls, however, there is always a thermal-stable layer, which would greatly decrease their heat storage capacity. To solve this problem, an active-passive ventilation wall with PCM has been developed in this study, and a comparative study was carried out using both experimental and numerical methods to justify its advantages over conventional walls. Several important parameters have been monitored or calculated to reflect the contribution of the newly proposed method to the performance of the middle layer of the wall, the indoor thermal environment and the plants’ growth. The obtained results confirmed the great effectiveness of the proposed wall in promoting the temperature of its middle layer and irradiated surface. In the newly proposed wall, there was no thermal-stable layer observed, resulting in a minimum temperature rise of 1.34 °C. The proposed solution also enhanced the wall's heat storage capacity by 35.27–47.89% and the heat release capacity by 49.93–60.21%, resulting in an average increase of indoor air temperature, daily effective accumulative temperature and soil temperature by 1.58–4.16 °C, 33.33–55.06% and 0.53–1.09 °C, respectively. The plant height, stem diameter and fruit yield have been increased by 30%, 25% and 28%, respectively.
Type: | Article |
---|---|
Title: | Thermal performance of an active-passive ventilation wall with phase change material in solar greenhouses |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1016/j.apenergy.2018.02.130 |
Publisher version: | http://dx.doi.org/10.1016/j.apenergy.2018.02.130 |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions. |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > UCL BEAMS UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of the Built Environment |
URI: | https://discovery.ucl.ac.uk/id/eprint/10045335 |