Zhang, S;
              
      
            
                Le, TT;
              
      
            
                Kabus, S;
              
      
            
                Su, B;
              
      
            
                Hausenloy, DJ;
              
      
            
                Cook, SA;
              
      
            
                Chin, CWL;
              
      
            
            
          
      
        
        
        
    
  
(2017)
  Cardiac magnetic resonance T1 and extracellular volume mapping with motion correction and co-registration based on fast elastic image registration.
Magnetic Resonance Materials in Physics, Biology and Medicine
      
    
    
    
         10.1007/s10334-017-0668-2.
   (In press).
  
       
    
  
| Preview | Text 10.1007%2Fs10334-017-0668-2.pdf - Published Version Download (3MB) | Preview | 
Abstract
OBJECTIVE: Our aim was to investigate the technical feasibility of a novel motion compensation method for cardiac magntic resonance (MR) T1 and extracellular volume fraction (ECV) mapping. MATERIALS AND METHODS: Native and post-contrast T1 maps were obtained using modified look-locker inversion recovery (MOLLI) pulse sequences with acquisition scheme defined in seconds. A nonrigid, nonparametric, fast elastic registration method was applied to generate motion-corrected T1 maps and subsequently ECV maps. Qualitative rating was performed based on T1 fitting-error maps and overlay images. Local deformation vector fields were produced for quantitative assessment. Intra- and inter-observer reproducibility were compared with and without motion compensation. RESULTS: Eighty-two T1 and 39 ECV maps were obtained in 21 patients with diverse myocardial diseases. Approximately 60% demonstrated clear quality improvement after motion correction for T1 mapping, particularly for the poor-rating cases (23% before vs 2% after). Approximately 67% showed further improvement with co-registration in ECV mapping. Although T1 and ECV values were not clinically significantly different before and after motion compensation, there was improved intra- and inter-observer reproducibility after motion compensation. CONCLUSIONS: Automated motion correction and co-registration improved the qualitative assessment and reproducibility of cardiac MR T1 and ECV measurements, allowing for more reliable ECV mapping.
| Type: | Article | 
|---|---|
| Title: | Cardiac magnetic resonance T1 and extracellular volume mapping with motion correction and co-registration based on fast elastic image registration | 
| Location: | Germany | 
| Open access status: | An open access version is available from UCL Discovery | 
| DOI: | 10.1007/s10334-017-0668-2 | 
| Publisher version: | https://doi.org/10.1007/s10334-017-0668-2 | 
| Language: | English | 
| Additional information: | This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. | 
| Keywords: | Co-registration, Diffuse fibrosis, Extracellular volume, Motion correction, T1 relaxation time | 
| UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Pre-clinical and Fundamental Science | 
| URI: | https://discovery.ucl.ac.uk/id/eprint/10041118 | 
Archive Staff Only
|  | View Item | 
 
                      