UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Note: Design and realization of a portable edge illumination X-ray phase contrast imaging system

Basta, D; Endrizzi, M; Vittoria, FA; Kallon, GKN; Millard, TPM; Diemoz, PC; Olivo, A; (2015) Note: Design and realization of a portable edge illumination X-ray phase contrast imaging system. Review of Scientific Instruments , 86 (9) , Article 096102. 10.1063/1.4930238. Green open access

[thumbnail of Basta_RSInote_revised.pdf]
Preview
Text
Basta_RSInote_revised.pdf

Download (313kB) | Preview

Abstract

We discuss a portable edge illumination x-ray phase contrast imaging system based on compact piezoelectric motors, which enables its transportation to different environments, e.g., hosting different x-ray source technologies. The analysis of images of standard samples reveals an angular sensitivity of 270 ± 6 nrad, which compares well with the 260 ± 10 nrad reported for previous systems based on stepper motors, demonstrating that system portability can be achieved without affecting phase sensitivity. The results can also be considered a test of the performance of the piezoelectric motors, and as such could be of interest to researchers planning their use in other imaging systems.

Type: Article
Title: Note: Design and realization of a portable edge illumination X-ray phase contrast imaging system
Location: USA
Open access status: An open access version is available from UCL Discovery
DOI: 10.1063/1.4930238
Publisher version: http://dx.doi.org/10.1063/1.4930238
Language: English
Additional information: Copyright 2015 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in: Basta, D; Endrizzi, M; Vittoria, FA; Kallon, GKN; Millard, TPM; Diemoz, PC; Olivo, A; (2015) Note: Design and realization of a portable edge illumination X-ray phase contrast imaging system. Review of Scientific Instruments , 86 (9) , Article 096102., and may be found at http://dx.doi.org/10.1063/1.4930238
Keywords: x-ray phase contrast imaging, portable systems, piezoelectric technology, angular sensitivity
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Med Phys and Biomedical Eng
URI: https://discovery.ucl.ac.uk/id/eprint/1471082
Downloads since deposit
148Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item