Swab pooling enables rapid expansion of high-throughput capacity for SARS-CoV-2 community testing

Fagg, J; Beale, R; Futschik, ME; Turek, E; Chapman, D; Halstead, S; Jones, M; ... Fowler, T; + view all (2023) Swab pooling enables rapid expansion of high-throughput capacity for SARS-CoV-2 community testing. Journal of Clinical Virology , 167 , Article 105574. 10.1016/j.jcv.2023.105574. Green open access

[thumbnail of 1-s2.0-S138665322300197X-main.pdf]
Preview
Text
1-s2.0-S138665322300197X-main.pdf - Published Version

Download (1MB) | Preview

Abstract

Background: The challenges of rapid upscaling of testing capacity were a major lesson from the COVID-19 pandemic response. The need for process adjustments in high-throughput testing laboratories made sample pooling a challenging option to implement. / Objective: This study aimed to evaluate whether pooling samples at source (swab pooling) was as effective as qRT-PCR testing of individuals in identifying cases of SARS-CoV-2 in real-world community testing conditions using the same high-throughput pipeline. / Methods: Two cohorts of 10 (Pool10: 1,030 participants and 103 pools) and 6 (Pool6: 1,284 participants and 214 pools) samples per pool were tested for concordance, sensitivity, specificity, and Ct value differences with individual testing as reference. Results: Swab pooling allowed unmodified application of an existing high-throughput SARS-Cov-2 testing pipeline with only marginal loss of accuracy. For Pool10, concordance was 98.1% (95% Confidence interval: 93.3–99.8%), sensitivity was 95.7% (85.5–99.5%), and specificity was 100.0% (93.6–100.0%). For Pool6, concordance was 97.2% (94.0–99.0%), sensitivity was 97.5% (93.7–99.3%), and specificity was 96.4% (87.7–99.6%). Differences of outcomes measure between pool size were not significant. Most positive individual samples, which were not detected in pools, had very low viral concentration. If only individual samples with a viral concentration > 400 copies/ml (i.e. Ct value < 30) were considered positive, the overall sensitivity of pooling increased to 99.5%. / Conclusion: The study demonstrated high sensitivity and specificity by swab pooling and the immediate capability of high-throughput laboratories to implement this method making it an option in planning of rapid upscaling of laboratory capacity for future pandemics.

Type: Article
Title: Swab pooling enables rapid expansion of high-throughput capacity for SARS-CoV-2 community testing
Location: Netherlands
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.jcv.2023.105574
Publisher version: https://doi.org/10.1016/j.jcv.2023.105574
Language: English
Additional information: Copyright © 2023 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Keywords: COVID-19, Community testing, High-throughput, Pool testing, SARS-CoV-2, Swab pooling
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Medicine > Renal Medicine
URI: https://discovery.ucl.ac.uk/id/eprint/10177166
Downloads since deposit
12Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item