UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Use of fluorescence imaging and indocyanine green during colorectal surgery: Results of an intercontinental Delphi survey

Wexner, S; Abu-Gazala, M; Boni, L; Buxey, K; Cahill, R; Carus, T; Chadi, S; ... Rosenthal, RJ; + view all (2022) Use of fluorescence imaging and indocyanine green during colorectal surgery: Results of an intercontinental Delphi survey. Surgery , 172 (6) S38-S45. 10.1016/j.surg.2022.04.016. Green open access

[thumbnail of 1-s2.0-S0039606022002458-main.pdf]
Preview
Text
1-s2.0-S0039606022002458-main.pdf - Published Version

Download (319kB) | Preview

Abstract

BACKGROUND: Fluorescence imaging with indocyanine green is increasingly being used in colorectal surgery to assess anastomotic perfusion, and to detect sentinel lymph nodes. METHODS: In this 2-round, online, Delphi survey, 35 international experts were asked to vote on 69 statements pertaining to patient preparation and contraindications to fluorescence imaging during colorectal surgery, indications, technical aspects, potential advantages/disadvantages, and effectiveness versus limitations, and training and research. Methodological steps were adopted during survey design to minimize risk of bias. RESULTS: More than 70% consensus was reached on 60 of 69 statements, including moderate-strong consensus regarding fluorescence imaging's value assessing anastomotic perfusion and leak risk, but not on its value mapping sentinel nodes. Similarly, although consensus was reached regarding most technical aspects of its use assessing anastomoses, little consensus was achieved for lymph-node assessments. Evaluating anastomoses, experts agreed that the optimum total indocyanine green dose and timing are 5 to 10 mg and 30 to 60 seconds pre-evaluation, indocyanine green should be dosed milligram/kilogram, lines should be flushed with saline, and indocyanine green can be readministered if bright perfusion is not achieved, although how long surgeons should wait remains unknown. The only consensus achieved for lymph-node assessments was that 2 to 4 injection points are needed. Ninety-six percent and 100% consensus were reached that fluorescence imaging will increase in practice and research over the next decade, respectively. CONCLUSION: Although further research remains necessary, fluorescence imaging appears to have value assessing anastomotic perfusion, but its value for lymph-node mapping remains questionable.

Type: Article
Title: Use of fluorescence imaging and indocyanine green during colorectal surgery: Results of an intercontinental Delphi survey
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.surg.2022.04.016
Publisher version: https://doi.org/10.1016/j.surg.2022.04.016
Language: English
Additional information: This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Keywords: Humans, Indocyanine Green, Colorectal Surgery, Optical Imaging, Sentinel Lymph Node Biopsy, Digestive System Surgical Procedures
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Targeted Intervention
URI: https://discovery.ucl.ac.uk/id/eprint/10161813
Downloads since deposit
20Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item