UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Seismic Performance of Exposed Column-Base Plate Connections with Ductile Anchor Rods

Hassan, AS; Song, B; Galasso, C; Kanvinde, A; (2022) Seismic Performance of Exposed Column-Base Plate Connections with Ductile Anchor Rods. Journal of Structural Engineering , 148 (5) , Article 04022028. 10.1061/(ASCE)ST.1943-541X.0003298. Green open access

[thumbnail of Song_et_al.pdf]
Preview
Text
Song_et_al.pdf - Accepted Version

Download (11MB) | Preview

Abstract

This paper presents full-scale experiments and computational analyses on exposed column-base plate connections with ductile anchors. The aim is to examine the seismic performance of these connections for their prospective use as weak bases, wherein steel moment frames are designed to concentrate inelastic rotations in the base connections rather than in the connected columns. The connections feature upset thread anchor rods in which the threads are milled to a smooth shank, providing a designated stretch length over which inelastic deformations may be concentrated. The shank is frictionally isolated from the footing using polyethylene tape. The four full-scale experiments investigate the effects of axial force, rod diameter, and rod material grade. The test specimens withstand (without anchor rod failure) the application of two Applied Technology Council-the Joint Venture partners of the Structural Engineers Association of California, the Applied Technology Council, and the Consortium of Universities for Research in Earthquake Engineering (ATC-SAC) protocols applied consecutively (each to drift amplitudes of 5%), followed by additional cycles to 6.5% drift amplitude. Complementary line element-based and continuum finite-element simulations are conducted to examine to what extent the experimentally observed response may be generalized to untested configurations. Implications for design are summarized, along with the limitations of the study.

Type: Article
Title: Seismic Performance of Exposed Column-Base Plate Connections with Ductile Anchor Rods
Open access status: An open access version is available from UCL Discovery
DOI: 10.1061/(ASCE)ST.1943-541X.0003298
Publisher version: https://doi.org/10.1061/(ASCE)ST.1943-541X.0003298
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Science & Technology, Technology, Construction & Building Technology, Engineering, Civil, Engineering, Column bases, Moment frames, Steel connections, Dissipative connections, MOMENT FRAMES, BEHAVIOR
UCL classification: UCL
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Civil, Environ and Geomatic Eng
URI: https://discovery.ucl.ac.uk/id/eprint/10161615
Downloads since deposit
166Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item