UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial

Knops, Reinoud E; Pepplinkhuizen, Shari; Delnoy, Peter Paul HM; Boersma, Lucas VA; Kuschyk, Juergen; El-Chami, Mikhael F; Bonnemeier, Hendrik; ... Olde Nordkamp, Louise RA; + view all (2022) Device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial. European Heart Journal , 43 (47) pp. 4872-4883. 10.1093/eurheartj/ehac496. Green open access

[thumbnail of ehac496.pdf]
Preview
Text
ehac496.pdf

Download (1MB) | Preview

Abstract

BACKGROUND: The subcutaneous ICD (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS: The PRAETORIAN trial is an international, multicenter, randomised trial in which 849 patients with an indication for ICD therapy were randomised to receive an SICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections and the need for invasive interventions. RESULTS: Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group 49 complications occurred in 44 patients of which lead-dysfunction was most frequent (HR 0.69; P =0.11). In both groups half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared to the TV-ICD group (P <0.001, P =0.03 respectively). Significantly more complications required invasive interventions in the TV-ICD group compared to the S-ICD group (8.3% vs. 4.3%, HR 0.59; P =0.047). CONCLUSIONS: This secondary analysis shows that, lead-related complications and systemic infections are more prevalent in the TV-ICD group compared to the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision making in clinical practice.

Type: Article
Title: Device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial
Location: England
Open access status: An open access version is available from UCL Discovery
DOI: 10.1093/eurheartj/ehac496
Publisher version: https://doi.org/10.1093/eurheartj/ehac496
Language: English
Additional information: © The Author(s) 2022. Published by Oxford University Press on behalf of European Society of Cardiology. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
URI: https://discovery.ucl.ac.uk/id/eprint/10155232
Downloads since deposit
49Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months