UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Parametric Design of Femoral Implant with Gradient Porous Structure

Gao, Xiangsheng; Zhao, Yuhang; Wang, Min; Liu, Ziyu; Liu, Chaozong; (2022) Parametric Design of Femoral Implant with Gradient Porous Structure. Frontiers in Bioengineering and Biotechnology , 10 , Article 850184. 10.3389/fbioe.2022.850184. Green open access

[thumbnail of Liu_fbioe-10-850184.pdf]
Preview
Text
Liu_fbioe-10-850184.pdf

Download (4MB) | Preview

Abstract

Patients who has been implanted with hip implant usually undergo revision surgery. The reason is that high stiff implants would cause non-physiological distribution loadings, which is also known as stress shielding, and finally lead to bone loss and aseptic loosening. Titanium implants are widely used in human bone tissues; however, the subsequent elastic modulus mismatch problem has become increasingly serious, and can lead to stress-shielding effects. This study aimed to develop a parametric design methodology of porous titanium alloy hip implant with gradient elastic modulus, and mitigate the stress-shielding effect. Four independent adjustable dimensions of the porous structure were parametrically designed, and the Kriging algorithm was used to establish the mapping relationship between the four adjustable dimensions and the porosity, surface-to-volume ratio, and elastic modulus. Moreover, the equivalent stress on the surface of the femur was optimized by response surface methodology, and the optimal gradient elastic modulus of the implant was obtained. Finally, through the Kriging approximation model and optimization results of the finite element method, the dimensions of each segment of the porous structure that could effectively mitigate the stress-shielding effect were determined. Experimental results demonstrated that the parameterized design method of the porous implant with gradient elastic modulus proposed in this study increased the strain value on the femoral surface by 17.1% on average. Consequently, the stress-shielding effect of the femoral tissue induced by the titanium alloy implant was effectively mitigated.

Type: Article
Title: Parametric Design of Femoral Implant with Gradient Porous Structure
Open access status: An open access version is available from UCL Discovery
DOI: 10.3389/fbioe.2022.850184
Publisher version: https://doi.org/10.3389/fbioe.2022.850184
Language: English
Additional information: Copyright © 2022 Gao, Zhao, Wang, Liu and Liu. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
Keywords: hip implant, stress-shielding, kriging algorithm, gradient porous structure, parametric design
UCL classification: UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci > Department of Ortho and MSK Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Medical Sciences > Div of Surgery and Interventional Sci
URI: https://discovery.ucl.ac.uk/id/eprint/10148620
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item