Feasibility and Validity of Computed Tomography-Derived Fractional Flow Reserve in Patients With Severe Aortic Stenosis: The CAST-FFR Study.
Cardiovascular Interventions
, 14
(1)
, Article e009586. 10.1161/CIRCINTERVENTIONS.120.009586.
Preview |
Text
Michail_381098_3_merged_1600791119.pdf - Accepted Version Download (2MB) | Preview |
Abstract
BACKGROUND: Coronary artery disease is common in patients with severe aortic stenosis. Computed tomography-derived fractional flow reserve (CT-FFR) is a clinically used modality for assessing coronary artery disease, however, its use has not been validated in patients with severe aortic stenosis. This study assesses the safety, feasibility, and validity of CT-FFR in patients with severe aortic stenosis. METHODS: Prospectively recruited patients underwent standard-protocol invasive FFR and coronary CT angiography (CTA). CTA images were analyzed by central core laboratory (HeartFlow, Inc) for independent evaluation of CT-FFR. CT-FFR data were compared with FFR (ischemia defined as FFR ≤0.80). RESULTS: Forty-two patients (68 vessels) underwent FFR and CTA; 39 patients (92.3%) and 60 vessels (88.2%) had interpretable CTA enabling CT-FFR computation. Mean age was 76.2±6.7 years (71.8% male). No patients incurred complications relating to premedication, CTA, or FFR protocol. Mean FFR and CT-FFR were 0.83±0.10 and 0.77±0.14, respectively. CT calcium score was 1373.3±1392.9 Agatston units. On per vessel analysis, there was positive correlation between FFR and CT-FFR (Pearson correlation coefficient, R=0.64, P<0.0001). Sensitivity, specificity, positive predictive value, and negative predictive values were 73.9%, 78.4%, 68.0%, and 82.9%, respectively, with 76.7% diagnostic accuracy. The area under the receiver-operating characteristic curve for CT-FFR was 0.83 (0.72-0.93, P<0.0001), which was higher than that of CTA and quantitative coronary angiography (P=0.01 and P<0.001, respectively). Bland-Altman plot showed mean bias between FFR and CT-FFR as 0.059±0.110. On per patient analysis, the sensitivity, specificity, positive predictive, and negative predictive values were 76.5%, 77.3%, 72.2%, and 81.0% with 76.9% diagnostic accuracy. The per patient area under the receiver-operating characteristic curve analysis was 0.81 (0.67-0.95, P<0.0001). CONCLUSIONS: CT-FFR is safe and feasible in patients with severe aortic stenosis. Our data suggests that the diagnostic accuracy of CT-FFR in this cohort potentially enables its use in clinical practice and provides the foundation for future research into the use of CT-FFR for coronary evaluation pre-aortic valve replacement.
Type: | Article |
---|---|
Title: | Feasibility and Validity of Computed Tomography-Derived Fractional Flow Reserve in Patients With Severe Aortic Stenosis: The CAST-FFR Study |
Location: | United States |
Open access status: | An open access version is available from UCL Discovery |
DOI: | 10.1161/CIRCINTERVENTIONS.120.009586 |
Publisher version: | https://doi.org/10.1161/CIRCINTERVENTIONS.120.0095... |
Language: | English |
Additional information: | This version is the author accepted manuscript. For information on re-use, please refer to the publisher's terms and conditions. |
Keywords: | aortic valve stenosis, calcium, coronary artery disease, coronary stenosis, physiology, transcatheter aortic valve replacement |
UCL classification: | UCL UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine |
URI: | https://discovery.ucl.ac.uk/id/eprint/10122195 |
Archive Staff Only
View Item |