Design of an In Vitro Mock Circulatory Loop to Reproduce Patient-Specific Vascular Conditions: Toward Precision Medicine

Franzetti, G; Díaz-Zuccarini, V; Balabani, S; (2019) Design of an In Vitro Mock Circulatory Loop to Reproduce Patient-Specific Vascular Conditions: Toward Precision Medicine. Journal of Engineering and Science in Medical Diagnostics and Therapy , 2 (4) , Article 041004. 10.1115/1.4044488. Green open access

[thumbnail of Franzetti_JESMDT-19-1022 - Balabani_cover sheet.pdf]
Preview
Text
Franzetti_JESMDT-19-1022 - Balabani_cover sheet.pdf - Accepted Version

Download (4MB) | Preview

Abstract

Patient-specific hemodynamic studies have attracted considerable attention in recent years due to their potential to improve diagnosis and optimize clinical treatment of cardiovascular diseases. Personalized computational models have been extensively investigated as a tool to improve clinical outcomes and are often validated against in vitro experimental data. Replicating patient-specific conditions in vitro is thus becoming increasingly important in cardiovascular research; experimental platforms can not only allow validation of in silico approaches but can also enable physical testing of various intervention scenarios and medical devices. Current experimental approaches suffer from shortcomings regarding personalization and biomimicry. To address some of these limitations, we have designed and developed a novel in vitro platform for the study of complex patient-specific vascular pathologies. This is achieved by using novel tunable three-element Windkessel vasculature simulators and a computer controlled pulsatile pump, coupled with mathematical models and computer routines to calibrate the parameters according to the available clinical datasets. In particular, the vessel inlet flow rate waveform and the afterload resistances and compliances are tuned in order to obtain target systolic and diastolic pressures, and cardiac output (CO) distribution. Pulse frequency (40–70 bpm), CO (2–5 l/min), resistance (0.03–10.6 mmHg s/ml), and compliance (0.07–1 ml/mmHg) values have been tested and the overall reliability of the platform components as well as its computer routines to reproduce controlled physiological conditions demonstrated.

Type: Article
Title: Design of an In Vitro Mock Circulatory Loop to Reproduce Patient-Specific Vascular Conditions: Toward Precision Medicine
Open access status: An open access version is available from UCL Discovery
DOI: 10.1115/1.4044488
Publisher version: https://doi.org/10.1115/1.4044488
Language: English
Additional information: This author accepted manuscript is distributed under the Creative Commons Attribution 4.0 International (CC BY 4.0) Licence (https://creativecommons.org/licenses/by/4.0/) after an initial twelve-month embargo period.
Keywords: Design, Flow (Dynamics), Physiology, Pumps, Pistons, Vessels, Pressure, Computers
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Mechanical Engineering
URI: https://discovery.ucl.ac.uk/id/eprint/10109598
Downloads since deposit
168Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item