UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Evaluation of ECG Imaging to Map Hemodynamically Stable and Unstable Ventricular Arrhythmias

Graham, AJ; Orini, M; Zacur, E; Dhillon, G; Daw, H; Srinivasan, NT; Martin, C; ... Lambiase, PD; + view all (2020) Evaluation of ECG Imaging to Map Hemodynamically Stable and Unstable Ventricular Arrhythmias. Circulation: Arrhythmia and Electrophysiology , 13 (2) , Article e007377. 10.1161/CIRCEP.119.007377. Green open access

[thumbnail of Orini_Endocardial Validation of ECGI during VT - untracked.pdf]
Preview
Text
Orini_Endocardial Validation of ECGI during VT - untracked.pdf - Accepted Version

Download (1MB) | Preview

Abstract

BACKGROUND: ECG imaging (ECGI) has been used to guide treatment of ventricular ectopy and arrhythmias. However, the accuracy of ECGI in localizing the origin of arrhythmias during catheter ablation of ventricular tachycardia (VT) in structurally abnormal hearts remains to be fully validated. METHODS: During catheter ablation of VT, simultaneous mapping was performed using electroanatomical mapping (CARTO, Biosense-Webster) and ECGI (CardioInsight, Medtronic) in 18 patients. Sites of entrainment, pace-mapping, and termination during ablation were used to define the VT site of origin (SoO). Distance between SoO and the site of earliest activation on ECGI were measured using co-registered geometries from both systems. The accuracy of ECGI versus a 12-lead surface ECG algorithm was compared. RESULTS: A total of 29 VTs were available for comparison. Distance between SoO and sites of earliest activation in ECGI was 22.6, 13.9 to 36.2 mm (median, first to third quartile). ECGI mapped VT sites of origin onto the correct AHA segment with higher accuracy than a validated 12-lead ECG algorithm (83.3% versus 38.9%; P=0.015). CONCLUSIONS: This simultaneous assessment demonstrates that CardioInsight localizes VT circuits with sufficient accuracy to provide a region of interest for targeting mapping for ablation. Resolution is not sufficient to guide discrete radiofrequency lesion delivery via catheter ablation without concomitant use of an electroanatomical mapping system but may be sufficient for segmental ablation with radiotherapy.

Type: Article
Title: Evaluation of ECG Imaging to Map Hemodynamically Stable and Unstable Ventricular Arrhythmias
Location: United States
Open access status: An open access version is available from UCL Discovery
DOI: 10.1161/CIRCEP.119.007377
Publisher version: http://dx.doi.org/10.1161/CIRCEP.119.007377
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: catheter ablation, consensus, electrodes, magnetic resonance imaging, tachycardia, ventricular
UCL classification: UCL
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Clinical Science
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Population Health Sciences > Institute of Cardiovascular Science > Population Science and Experimental Medicine > MRC Unit for Lifelong Hlth and Ageing
URI: https://discovery.ucl.ac.uk/id/eprint/10093401
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item