UCL Discovery
UCL home » Library Services » Electronic resources » UCL Discovery

Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging

Kujawa, A; Kim, M; Demetriou, E; Anemone, A; Longo, DL; Zaiss, M; Golay, X; (2019) Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging. Journal of Magnetic Resonance , 300 pp. 120-134. 10.1016/j.jmr.2019.01.006. Green open access

[thumbnail of Golay JMRxxRev.pdf]
Preview
Text
Golay JMRxxRev.pdf - Accepted Version

Download (2MB) | Preview

Abstract

Fitting a model based on the Bloch-McConnell (BM) equations to Chemical Exchange Saturation Transfer (CEST) spectra allows for the quantification of metabolite concentration and exchange rate as well as simultaneous correction of field inhomogeneity, direct water saturation and magnetization transfer. Employing a Bayesian fitting approach permits the integration of prior information into the analysis to incorporate expected parameter distributions and to prevent over-fitting. However, the analysis can be time consuming if a general numerical solution of the BM equations is applied. In this study, we combined a Bayesian fitting algorithm with approximate analytical solutions of the BM equations to achieve feasible computational times. To evaluate the accuracy and speed of the suggested approach, phantoms including Iodipamide, Taurine and Creatine were tested in addition to simulated data with continuous-wave (CW) and pulsed saturation with Gaussian pulses. A significant reduction of computational time was achieved when fitting CW data (about 50-fold) and pulsed saturation data (more than 100-fold) with the analytical model while the estimated parameters were largely consistent with the parameters from the general numerical solution. The increased speed of the algorithm facilitates the Bayesian analysis of CEST data within clinically feasible processing times. Other analytical models valid for different parameter regimes may be employed to extend the applicability to a wider range of CEST agents.

Type: Article
Title: Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging
Open access status: An open access version is available from UCL Discovery
DOI: 10.1016/j.jmr.2019.01.006
Publisher version: https://doi.org/10.1016/j.jmr.2019.01.006
Language: English
Additional information: This version is the author accepted manuscript. For information on re-use, please refer to the publisher’s terms and conditions.
Keywords: Chemical exchange saturation transfer, Pulsed saturation, Amide proton transfer
UCL classification: UCL
UCL > Provost and Vice Provost Offices
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology
UCL > Provost and Vice Provost Offices > School of Life and Medical Sciences > Faculty of Brain Sciences > UCL Queen Square Institute of Neurology > Brain Repair and Rehabilitation
UCL > Provost and Vice Provost Offices > UCL BEAMS
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Chemical Engineering
UCL > Provost and Vice Provost Offices > UCL BEAMS > Faculty of Engineering Science > Dept of Computer Science
URI: https://discovery.ucl.ac.uk/id/eprint/10067362
Downloads since deposit
0Downloads
Download activity - last month
Download activity - last 12 months
Downloads by country - last 12 months

Archive Staff Only

View Item View Item